![Eaton Green Motion DC 22 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/eaton/green-motion-dc-22/green-motion-dc-22_installation-manual_524612023.webp)
19
GREEN MOTION DC 22 EV CHARGER INSTALLATION MANUAL
MN192004EN November 2022 www.eaton.com
00
Title
5.2.3 Mounting on the floor-mount pedestal (optional)
Mounting the column to the concrete floor
Fix the pedestal with four M10 x 100 mm (min.) stainless steel threaded rods on a 400 mm x 700 mm x 150 mm
concrete base. Use the flat washers to secure the mounting.
The AC grid power cable is fed through the left opening of the floor-mounted pedestal. Make sure the concrete base
provides an unobstructed path for the power cable.
Below is a schematic representation of the base of the EV charger column to be mounted on the concrete base.
Figure 13. The base of the EV charger column with dimensions
Tag
Description
1
Concrete base
2
Hole for electrical cables
3
M10 stainless steel threaded rods
A
Top view of the concrete base
B
Overview of floor-mounted pedestal on concrete base.
When choosing the location of the floor-mount pedestal, consider a 300-mm free space requirement to the
left and right sides of the EV charger for air circulation.
350
50
100
120
200
235
540
ø16
ø40
700
115
400
200
700 mm (27.6 inch)
400 mm (15.7 inch)
175 mm
(6.9 inch)
350 mm
(13.8 inch)
140 mm (5.5 inch)
120 mm (4.7 inch)
115 mm
(4.5 inch)
200 mm (7.9 inch)
3
3
3
3
2
1
2
3
1