Object 3 [Index 3]
Byte 0: Device type, status information 2
Bit
7
6
5
4
3
2
1
0
Configura-
tion
OL-WARN MAINS
FAILURE
–
OK
TYPE
(MSB)
TYPE
TYPE
TYPE
(LSB)
Bit
Designation
Meaning
0, 1, 2, 3
TYPE
Type of motor starter EMS2-…-SWD
4
OK
1
: The device is activated and current is flowing.
5
–
Not used
6
MAINS FAILURE
1
: The device is activated; but there is no current.
7
OL-WARN
Current calculated thermal load of the motor
0
: Load < 105 % of the set current I
n
1
: Load > 105 % of the set current I
n
Bit 3
Bit 2
Bit 1
Bit 0 Type
0
0
0
0
not used
0
0
0
1
not used
0
0
1
0
not used
0
0
1
1
not used
0
1
0
0
EMS2-DO-T-3-SWD
0
1
0
1
EMS2-RO-T-3-SWD
0
1
1
0
EMS2-DOS-T-3-SWD
0
1
1
1
EMS2-ROS-T-3-SWD
1
0
0
0
EMS2-DO-T-9-SWD
1
0
0
1
EMS2-RO-T-9-SWD
1
0
1
0
EMS2-DOS-T-9-SWD
1
0
1
1
EMS2-ROS-T-9-SWD
1
1
0
0
not used
1
1
0
1
not used
1
1
1
0
not used
1
1
1
1
not used
Содержание EMS2 SWD Series
Страница 1: ...Manual EMS2 SWD Electronic motor starters with SWD 10 19 MN120008EN ...
Страница 4: ......
Страница 58: ...7 Technical data 54 EMS2 SWD Electronic motor starter 10 19 MN120008EN www eaton com ...
Страница 60: ...8 Dimensions 56 EMS2 SWD Electronic motor starter 10 19 MN120008EN www eaton com ...