15
Instruction leaflet
IL05407001E
Effective October 2010
E5-648-C446x electronic preset
counter with four presets (relays)
LCD negative, red-green backlighting
eaton corporation
www.eaton.com
10.5 Signal and control inputs
•
Polarity: programmable NPN/PNP for all inputs in common
•
Input resistance: 5 kohms
•
Pulse shape: any
•
Switching level with AC supply:
•
HTL level: Low: 0–4 Vdc; High: 12–30 Vdc
•
5V level: Low: 0–2Vdc; High: 3.5–30 Vdc
•
Switching level with DC supply:
•
HTL level: Low: 0–0.2 x UB; High: 0.6 x UB–30 Vdc
5V level: Low: 0–2 Vdc; High: 3.5–30 Vdc
•
Minimum pulse length of the Reset input: 1 ms
•
Minimum pulse length of the Control inputs: 10 ms
10.6 Outputs
Output 1
•
Relay with make contact programmable as NC or NO
•
Switching voltage: max. 250 Vac/110 Vdc
•
Switching current: max. 3A AC/Vdc, min. 30 mA DC
•
Switching capacity: max. 750 VA/90W
•
Mechanical service life (switching cycles): 2 x 10
7
•
Number of switching cycles at 3A/250 Vac: 1 x 10
5
•
Number of switching cycles at 3A/30 Vdc: 1 x 10
5
Output 2
•
Relay with changeover contact
•
Switching voltage: max. 250 Vac/150 Vdc
•
Switching current: max. 3A AC/A DC, min. 30 mA DC
•
Switching capacity: max. 750 VA/90W
•
Mechanical service life (switching cycles): 20 x 10
6
•
Number of switching cycles at 3A/250 Vac: 5 x 10
4
•
Number of switching cycles at 3A/30 Vdc: 5 x 10
4
Output 3
•
Relay with make contact
•
Switching voltage: max. 125 Vac/110 Vdc
•
Switching current: max. 1A AC/1A DC, min. 1 mA AC/DC
•
Switching capacity: max. 62.5 VA/30W
•
Mechanical service life (switching cycles): 5 x 10
7
•
Number of switching cycles at 0.5A/125 Vac: 1 x 10
5
•
Number of switching cycles at 1A/30 Vdc: 1 x 10
5
Output 4
•
Relay with changeover contact
•
Switching voltage: max. 125 Vac/110 Vdc
•
Switching current: max. 1A AC/1A DC, min. 1 mA AC/DC
•
Switching capacity: max. 62.5 VA/30W
•
Mechanical service life (switching cycles): 5 x 10
7
•
Number of switching cycles at 0.5A/125 Vac: 1 x 10
5
•
Number of switching cycles at 1A/30 Vdc: 1 x 10
5
10.7 Supply voltage
•
AC supply
•
90–260 Vac/max. 8 VA 50/60 Hz
•
Ext. fuse protection: T 0.1A
•
DC supply
•
10–30 Vdc/max. 1.5W reverse polarity protection
•
Ext. fuse protection T 0.2A
10.8 Sensor supply voltage
•
AC supply: 24 Vdc ±15%, 80 mA
•
DC supply: max. 80 mA, external voltage supply
is connected through
10.9 Climatic conditions
•
Operating temperature: –20°C to 65°C
•
Storage temperature: –25°C to 75°C
•
Relative humidity: RH. 93% at 40°C, non-condensing
•
Altitude: to 2000m
10.10 EMC
•
Noise immunity: EN61000-6-2 with
shielded signal and control cables
•
Noise emission: EN55011 Class B
10.11 Device safety
•
Design to: EN61010 Part 1
•
Protection class: Class 2
•
Application area: Soiling Level 2
10.12 Mechanical data
•
Housing: Panel-mount housing to DIN 43 700, RAL 7021
•
Dimensions: 48 x 48 x 91 mm
•
Panel cut-out: 45
+0.6
x 45
+0.6
mm
•
Installation depth: ca. 107 mm incl. terminals
•
Weight: ca. 125g
•
Protection: IP 65 (front)
•
Housing material: Polycarbonate UL94 V-2
•
Vibration resistance: 10–55 Hz/1 mm/XYZ
(EN60068-2-6): 30 min in each direction
•
Shock resistance: 100G/XYZ
(EN60068-2-27): 3 times in each direction
(EN60068-2-29): 10G/6 ms/XYZ 2000 times in each direction
•
Cleaning: The front of the unit should only be cleaned
using a soft damp (water) cloth
10.13 Connections
•
Supply voltage and outputs
•
Plug-in screw terminal: 7-pin, RM 5.08
•
Core cross section: max. 2.5 mm²
•
Plug-in screw terminal: 5-pin, RM 3.81
•
Core cross-section: max. 1.5 mm²
•
Signal and control inputs:
•
Plug-in screw terminal: 8-pin, RM 3.81
•
Core cross-section: max. 1.5 mm²