Instruction leaflet 

IL05407001E

Effective October 2010

E5-648-C446x electronic preset 

counter with four presets (relays)

LCD negative, red-green backlighting

eaton corporation

 www.eaton.com

ADD mode output operations: 

timed signal at output 1, becomes  

active with positive direction and  

when count ≥ preset 1 and  

subsequently active with negative  

direction and when count ≤ preset 1  

SUB mode output operations: 

timed signal at output 1, becomes  

active with negative direction and  

when count ≤ preset 1 and  

subsequently active with positive  

direction and when count ≥ preset 1
ADD mode output operations: 

timed signal at output 1, becomes  

passive with positive direction and  

when count ≥ preset 1 and  

subsequently passive with negative  

direction and when count ≤ preset 1  

SUB mode output operations: 

timed output at output 1, becomes  

passive with negative direction and  

when count ≤ preset 1 and  

subsequently passive with positive  

direction and when count ≥ preset 1 
Duration of timed signal of output 1,  

programmable from 00.01 to 99.99s 

Timed signal is post-triggered

7.8.6.6  Main menu for preset 2

Main menu for preset 2

ADD mode output operations: 

permanent signal at output 2, becomes 

active when count ≥ preset 2  

SUB mode output operations: 

permanent signal at output 2, becomes 

active when count ≤ zero
ADD mode output operations: 

permanent signal at output 2, becomes  

passive when count ≥ preset 2  

SUB mode output operations: 

permanent signal at output 2, becomes  

passive when count ≤ zero
ADD mode output operations: 

timed signal at output 2, becomes  

active when count ≥ preset 2  

(Activation only in positive direction). 

SUB mode output operations: 

permanent signal at output 2,  

becomes active when count ≤ zero 

(Activation only in negative direction)
ADD mode output operations: 

timed signal at output 2, becomes  

passive when count ≥ preset 2 (Deactivation 

only in positive direction) 

SUB mode output operations: 

permanent signal at output 2,  

becomes passive when count ≤ zero 

(Deactivation only in negative direction)

ADD mode output operations: 

timed signal at output 2, becomes  

active with positive direction and  

when count ≥ preset 2 and  

subsequently with negative  

direction and when count ≤ preset 2  

SUB mode output operations: 

timed signal at output 2, becomes  

active with negative direction and  

when count ≤ zero and  

subsequently with positive  

direction and when count ≥ zero
ADD mode output operations: 

timed signal at output 2, becomes  

passive with positive direction and  

when count ≥ preset 2 and  

subsequently with negative  

direction and when count ≤ preset 2  

SUB mode output operations: 

timed signal at output 2, becomes  

passive with negative direction and  

when count ≤ zero and  

subsequently with positive  

direction and when count ≥ zero
Duration of timed signal of output 1,  

programmable from 00.01 to 99.99s 

Timed output is post-triggered

7.8.6.7  Main menu for preset 3 and 4

Only preset 3 is represented here

Main menu for preset 3 [4]

ADD mode output operations: 

permanent signal at output 3 [4], becomes 

active when count ≥ preset 3 [4]  

SUB mode output operations: 

permanent signal at output 3 [4], becomes 

active when count ≤ preset 3 [4] 
ADD mode output operations: 

permanent signal at output 3 [4], becomes 

passive when count ≥ preset 3 [4] 

SUB mode output operations: 

permanent signal at output 3 [4], becomes 

passive when count ≤ preset 3 [4]
ADD mode output operations: 

timed signal at output 3 [4], becomes  

active when count ≥ preset 3 [4].  

(Activation only in positive direction) 

SUB mode output operations: 

timed signal at output 3 [4], becomes  

active when count ≤ preset 3 [4].  

(Activation only in negative direction)
ADD mode output operations: 

timed signal at output 3 [4], becomes 

passive when count ≥ preset 3 [4]. 

(Deactivation only in positive direction) 

SUB mode output operations: 

timed signal at output 3 [4], becomes 

passive when count ≤ preset 3 [4]. 

(Deactivation only in negative direction)

Содержание E5-648-C446 Series

Страница 1: ...Effective October 2010 Instruction leaflet IL05407001E E5 648 C446x electronic preset counter with four presets relays LCD negative red green backlighting ...

Страница 2: ...5 7 8 1 Default parameters 5 7 8 2 Parameter sets 5 7 8 3 Setting the Basic function 6 7 8 4 Pulse counter 6 7 8 5 Tacho frequency meter 8 7 8 6 Timer 9 7 9 Setting the presets 13 7 9 1 Setting via decade keys 13 7 9 2 Setting with Teach In function 13 7 10 Set function 13 8 Error message 13 9 Connections 14 9 1 Signal and control inputs 14 9 2 Supply voltage and outputs 14 10 Technical data 14 10...

Страница 3: ...gasket is correctly seated 3 Slide the fixing clip from the rear onto the housing until the spring clamps are under tension and the upper and lower latching lugs have snapped into place 2 3 Electrical installation DANGER The device must be disconnected from the power supply before any installation or maintenance work is carried out AC powered devices must only be connected to the low voltage netwo...

Страница 4: ...no counting while active Frequency meter no counting while active Timer no time measurement while active Gate hi no time measurement while not active Gate Lo 5 4 Lock input Static keypad lock input for presets or programming Lock out level can be set in the programming menu 5 5 MPI Input Programmable as Display Latch Set or Teach In input 6 Outputs 6 1 Output 1 and output 3 Relay with potential fr...

Страница 5: ...or checked again Pressing the decade key T2 selects the termination of the programming The security prompt appears in the display Pressing the Prog Mode key acknowledges this prompt and terminates the programming the modified settings are saved in the EEPROM The text SAVE is displayed for 2s 7 8 Programming menu 7 8 1 Default parameters Three default parameter sets have been permanently stored the...

Страница 6: ...ut Differential counting A B INP A count input add INP B count input sub Totalizing A B INP A count input add INP B count input add Quadrature input INP A count input 0 INP B count input 90 Quadrature with pulse doubling INP A count input 0 INP B count input 90 Each pulse edge of INP A will be counted Quadrature x4 INP A count input 0 INP B count input 90 Each pulse edge of INP A and INP B will be...

Страница 7: ... counter Output 2 timed signal active when main counter preset value 2 Automatic reset to zero when main counter preset 2 Output 3 active when main counter preset value 3 Batch counter counts the number of automatic repetitions of preset 2 Output 1 resp 4 active when batch counter preset 1 resp 4 Manual reset sets both counters to zero Electrical reset only sets the main counter to zero Count mode...

Страница 8: ...input When the MPI input is activated the display is frozen and remains frozen until the MPI input is deactivated Internally the frequency meter continues running When the MPI input is activated the current frequency for the preset that has just been selected will be adopted as the new preset value See also 7 9 Display color for device E5 648 C446x Display color Upper line red Lower line red Displ...

Страница 9: ...solution 0 no decimal place 0 0 1 decimal place 0 00 2 decimal places 0 000 3 decimal places Moving average Moving average calculated AVG 2 over 2 measurements AVG 5 over 5 measurements AVG 10 over 10 measurements AVG 20 over 20 measurements Start delay Programmable from 00 0 to 99 9s At the start of a measurement the measurement results within this time period are ignored Waiting time Programmabl...

Страница 10: ...input When the Lock input is activated the programming is inhibited When the Lock input is activated the setting of the preset values is inhibited When the Lock input is activated the setting of the preset values and the programming are both inhibited 7 8 6 2 Main menu for output operations Main menu for determining the operation of the outputs Count mode ADD Outputs active when count status prese...

Страница 11: ...999999 A previously programmed decimal point will be displayed Display color for device E5 648 C446x Display color Upper line red Lower line red Display color Upper line red Lower line green 7 8 6 4 Main menu for reset mode Setting the reset mode Manual reset with red key and electrical reset reset input No reset possible red key and reset input inhibited Only electrical reset possible reset input...

Страница 12: ... preset 2 Deactivation only in positive direction SUB mode output operations permanent signal at output 2 becomes passive when count zero Deactivation only in negative direction ADD mode output operations timed signal at output 2 becomes active with positive direction and when count preset 2 and subsequently with negative direction and when count preset 2 SUB mode output operations timed signal at...

Страница 13: ...ia decade keys In operating mode preset 4 will be displayed in the lower line excepted for the output operations AddBat and AddTot Press the Prog Mode key until the preset to be changed is displayed or Press any decade key Display switches to the editor mode Set the desired preset value using the decade keys Press the Prog Mode key to confirm the value and save it Display switches to the editor mo...

Страница 14: ... O 4 19 Relay contact N O 3 Output 3 20 Relay contact C 3 10 Technical data 10 1 General data Display LCD positive or negative backlit 2 x 6 digit Digit height Upper line 9 mm Lower line 7 mm Special characters 2 mm Overload Blinking 1s Underload Counter loses up to 1 decade no pulses Data retention 10 years EEPROM Operation 8 keys 10 2 Pulse counter Count frequency max 50 kHz see section 13 Frequ...

Страница 15: ...Output 4 Relay with changeover contact Switching voltage max 125 Vac 110 Vdc Switching current max 1A AC 1A DC min 1 mA AC DC Switching capacity max 62 5 VA 30W Mechanical service life switching cycles 5 x 107 Number of switching cycles at 0 5A 125 Vac 1 x 105 Number of switching cycles at 1A 30 Vdc 1 x 105 10 7 Supply voltage AC supply 90 260 Vac max 8 VA 50 60 Hz Ext fuse protection T 0 1A DC su...

Страница 16: ...29 kHz 29 kHz 29 kHz 5V level Typ Low 1 0V Typ High 4 0V Display Add Sub AddAr SubAr AddBat AddTot Cnt Dir 9 kHz 1 3 kHz 1 6 kHz Up Dn Up Up 9 kHz 1 3 kHz 1 6 kHz Quad Quad 2 9 kHz 0 5 kHz 0 7 kHz Quad 4 9 kHz 0 5 kHz 0 7 kHz A B A B A 9 kHz 9 kHz 9 kHz E5 648 C446 x Supply voltage 1 90 to 260 Vac 2 10 to 20 Vdc 13 2 Frequency meter HTL level AC supply Typ Low 2 5V Typ High 22V DC supply 12V Typ L...

Страница 17: ...0 1 2 1 0 0 1 INP A INP B ADD SUB P P P P 1 P 1 P 1 P 2 Inp A Count input add Inp B Count input sub Add Display 0 Preset Sub Display Preset 0 Up Up 1 0 2 3 4 6 7 INP A INP B ADD Inp A Count input 1 add Inp B Count input 2 add Add Display 0 Preset Quad 0 1 2 3 2 1 0 P P 1 P 2 P 3 P 2 P 1 P INP A INP B ADD SUB A 90 B Inp A Count input Count on one edge Inp B Reverse direction Add Display 0 Preset Su...

Страница 18: ...P 4 P 5 P 5 P 6 P 6 P 7 2 3 3 4 4 5 5 6 6 7 A 90 B Inp A Count input Count on rising and on falling edges Inp B Count input Count on rising and on falling edges Reverse direction Add Display 0 Preset Sub Display Preset 0 A B 0 1 1 1 2 3 4 0 1 2 3 3 4 4 0 1 0 5 0 33 0 66 0 75 1 INP A Counts A INP B Counts B Display Inp A Count input 1 Inp B Count input 2 Formula A B A B A 0 1 1 1 2 3 4 0 1 2 3 3 4 ...

Страница 19: ...ub Display Preset 0 InB InB INP B GATE ADD SUB T1 T2 off on off 0 T1 T1 T2 P T1 T2 P T1 P Inp A no function Inp B Start Stop Add Display 0 Preset Sub Display Preset 0 FrRrun off T1 T2 on off GATE ADD SUB 0 T1 T1 T2 P T1 T2 P T1 P Inp A no function Inp B no function Control of the timing only via the GATE input Add Display 0 Preset Sub Display Preset 0 Auto off on off T1 T2 T3 T4 0 P P T1 P T2 P T2...

Страница 20: ...P A INP B Display Inp A Frequency input 1 Inp B Frequency input 2 Formula A B AaddB 0 0 x FA0 FA1 FA2 0 0 x FB0 FB1 FB2 0 0 FA0 FB2 FA0 FB0 FA1 _ FB1 INP A INP B Display Inp A Frequency input 1 Inp B Frequency input 2 Formula A B Quad 0 0 FA0 FA1 FA2 FA3 FA4 Display INP B INP A fA0 fA1 fA2 fA3 fA4 fA5 A 90 B Inp A Frequency input 1 Inp B Reverse direction A B 0 0 x FA0 FA1 FA2 0 0 x FB0 FB1 FB2 0 ...

Страница 21: ...dditionally in the mode and Add RESET PR2 PR1 PR3 PR4 COUNTER OUT P1 P3 P4 OUT P2 t t t t t Sub RESET PR2 PR1 PR3 PR4 COUNTER OUT P1 P3 P4 OUT P2 t t t t t AddAr t t t t t t RESET PR2 PR1 PR3 PR4 COUNTER OUT P1 P3 P4 OUT P2 SubAr t t t t t t RESET PR2 PR1 PR3 PR4 COUNTER OUT P1 P3 P4 OUT P2 AbbBat t t t t t t t t t RESET PR2 PR3 PR4 PR1 COUNTER BATCH OUT P1 OUT P4 OUT P3 OUT P2 t AddTot t t t t t ...

Страница 22: ... E5 648 C446x electronic preset counter with four presets relays LCD negative red green backlighting eaton corporation www eaton com 18 Dimensional drawings mm 48 48 45 15 5 91 7 4 25 max 10 5 Figure 2 Dimensional Drawing Figure 3 Panel Cut Out 45 0 6 45 0 6 ...

Страница 23: ...23 Instruction leaflet IL05407001E Effective October 2010 E5 648 C446x electronic preset counter with four presets relays LCD negative red green backlighting eaton corporation www eaton com Notes ...

Страница 24: ...s Reserved Printed in USA Publication No IL05407001E Z9872 October 2010 PowerChain Management is a registered trademark of Eaton Corporation All other trademarks are property of their respective owners Instruction leaflet IL05407001E Effective October 2010 E5 648 C446x electronic preset counter with four presets relays LCD negative red green backlighting ...

Отзывы: