background image

Technical Data

Page 14                  Effective: July 2003

PRC100 - Universal System Controller
& Enclosures

TD01412013E

                          For More Information Visit www.cutler-hammer.com

Pow-R-Command 100 In Integrated
Facility Systems Switchboards

An Integrated Facility Systems (IFS)
Switchboard is an innovative design created
by Eaton’s Cutler-Hammer designed to save
space, reduce construction cycle time, and
reduce labor and material requirements.

IFS Switchboards take loose panelboards,
switches, distribution transformers, and other
miscellaneous equipment and assemble them
into UL 891 listed freestanding switchboard
structure.  Pow-R-Command 100 panels fall
into the category of the typical types of
devices incorporated into IFS, Eaton’s Cutler-
Hammer has multiple options for integrating
Pow-R-Command into IFS.

IFS Switchboards are divided into structures.
Each structure may further be divided into two
sections.  Depending on the size of the
device intended for installation into IFS, it will
either occupy an entire structure or one
section.

Pow-R-Command 100 Panelboards In IFS
Structures

Depending on the amperage of the main
device of a panel, and the optional devices
incorporated into the Pow-R-Command 100
panelboard, it will fit in either a full structure or
an individual section of a structure.

 • 

Pow-R-Command 100 Panelboards In An

IFS Section: In order for a Pow-R-
Command 100 Panelboard to be mounted
in a single section it must have a main
device amperage rating of 250A or less for
main lugs, or 100A or less for main
breaker.  A Pow-R-Command 100
Panelboard intended to mount in a cell of
an IFS structure 

cannot

 contain an

expansion chassis, TVSS, through-feed
lugs, nor sub-feed breaker.

 • 

Pow-R-Command 100 Panelboards In An

Entire IFS Structure: When a Pow-R-
Command 100 panelboard is mounted in
an entire IFS structure, all optional
standard panelboard and Pow-R-
Command 100 Panelboard components
are available for use.  Also, the Pow-R-
Command 100 Panelboard may contain
up to a 400A main device (lugs or
breaker), sub-feed or through-feed devices
up to 225A.

Figure 11: Typical IFS Switchboard

For more information on IFS structures as
well as dimensions, please see 

Technical

Document TD01502003E

.

Mounting Other Pow-R-Command 100
Components In An IFS Switchboard

As a result of the engineering capabilities of
Eaton’s Cutler-Hammer, more then just Pow-
R-Command 100 Panelboards may be
mounted into an IFS Switchboard.  Though
Pow-R-Command 100 Panelboards are the
most frequently mounted product, all Pow-R-
Command 100 components are qualified for
mounting into IFS Switchboards.  This
includes all structures listed in this document
(with the exception of Pow-R-Command 100
Column Type Panelboards), and all other
control and network devices discussed in
other Pow-R-Command 100 Technical
Documents.  For more information on
mounting Pow-R-Command 100 equipment,
as well as other equipment, into IFS
Switchboards, please contact your local
Cutler-Hammer sales representative.

Содержание Cuttler-Hammer Pow-R-Command 100

Страница 1: ...uts 3 USC Input Output Specification 3 Integrated Timing Scheduling Features 3 Grouping Devices 3 Control Command Functions 3 On Board Indicator LED s 4 Networking Controllers 4 Locally Accessing A US...

Страница 2: ...he capabilities offered by the Pow R Command 100 controller the system would not have a great deal of use without enclosures Currently there are five general type of enclosures used in the Pow R Comma...

Страница 3: ...o use a master clock function in order to assure coordination of all USC s on a network The master clock is found on the Network Access Device For further information on Network Access Devices see Tec...

Страница 4: ...the Pow R Command 100 software installed For more information on using PC s with the Pow R Command 100 network see Technical Document TD01412016E For more information on the types of Pow R Command 10...

Страница 5: ...Thermostats may also be connected to analog inputs outputs Figure 4 Analog Output Wiring Common Analog Output 1 Analog Output 2 Black White Red Power Dimming Pigtail Red Black Universal System Contro...

Страница 6: ...t network The maximum distance of the Pow R Command 100 network is 4 000 Feet from the Network Access Device to the furthest controller on the network using a shielded twisted pair network cable SHLD...

Страница 7: ...ocally terminate the Pow R Command 100 network Breaker Termination Boards The Breaker Termination Boards are a control bus that runs underneath the load side terminals of the branch circuit breakers o...

Страница 8: ...BR BABRS BAB GHQRS 3 4 GHBS GHB BABR BABRS BAB GHQRS 3 4 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 13X PRC100 Smart Chassis 18 Single Pole Spaces for GHBS GHB BABR BABRS BAB GHQ...

Страница 9: ...s a control power bus to all devices attached to it Application Specific Controller Ports Located on the Relay Termination Board are three 3 sets of white connection ports These connection ports are u...

Страница 10: ...R Command 100 Control Cabinet is sold complete with all of the standard components of the Pow R Command 100 Relay Cabinet with the exception of the USC In addition the Pow R Command 100 Control Cabin...

Страница 11: ...former capable of operating at either 120 V ac or 277V ac Power to the trans former is drawn directly from the bus Additionally line protection is supplied to both the primary and secondary side of th...

Страница 12: ...Data Page 12 Effective July 2003 PRC100 Universal System Controller Enclosures TD01412013E For More Information Visit www cutler hammer com Panelboard T ypes M ain Breaker T ypes M ounting H Horizonta...

Страница 13: ...ox Pull box is furnished without knockouts Standard Dimensions 12 inches 304 8 mm high 16 inches 406 4 mm wide 6 inches 152 4 mm deep Panelboard T ypes M ain Breaker T ypes M ounting H Horizontal V V...

Страница 14: ...e mounted in a single section it must have a main device amperage rating of 250A or less for main lugs or 100A or less for main breaker A Pow R Command 100 Panelboard intended to mount in a cell of an...

Страница 15: ...TD01412015E PRC100 Human Machine Interfaces TD01412016E PRC100 JCI 100 Controller TD01412017E PRC100 Protocol Exchanges TD01412018E PRC100 0 10V dc Dimming Electronic Ballasts Control TD01412019E PRC...

Отзывы: