4.9.3 Install the studs (6) into the mounting flange (112).
The stud end with the shorter length of threads is to
be assembled into the mounting flange. Clean the
stud end to be assembled by applying Loctite
LocQuic
®
Primer Grade “T” to the threads. After the
threads have dried, apply Loctite
®
#271 to the threads
and assemble the stud until it bottoms in the
threaded hole in the mounting flange. Repeat for the
remaining studs.
Warning
Loctite
®
Primer “T” contains harmful vapors. Refer to
the product label for proper safety precautions.
Caution
The end of the stud (6) must not extend past the
mounting surface of the mounting flange/cylinder
(112).
4.9.4 Reference Figure 15 and Figure 15A and make the
Eaton Airflex logo the 12 o’clock position and the
drain plug (105) the 6 o’clock position. The centerline
of the tensioner running through the 12 o’clock
position will land between two studs (6). Place one
pair of clamp tubes (12) over the studs. Place the
next pair of clamp tubes over the studs that split the
3 o’clock position and repeat for the 6 & 9 o’clock
positions. Four pair of studs is required for a total of 8
studs.
Note: When building up the tensioner, the reaction plates (30) and
the end plate (117) should be aligned so the coolant inlets and
outlets are at the 12, 3, 6 & 9 o’clock positions with reference to
the Eaton Airflex logo and drain plug (105) as defined in 4.9.4
above and the reaction holes line up. The clamp tubes (12) are
placed through the reaction holes of the reaction plates and the
end plate.
4.9.5 Support Beam
4.9.5.1 Reference Figure 15 and Figure 15A Place a support
beam (138) over each pair of studs that are located
at 45 degrees to each pair of clamp tubes (12). Four
support beams are required. Be sure that the support
beam rests on the mounting flange/cylinder. There
should be no gap.
WCSB3 Brakes
OUTLET ORB
COOLING PORT
OUTLET ORB
COOLING PORT
INLET ORB
COOLING PORT
INLET ORB
COOLING PORT
Stud & Clamp Tube
Position Pair
Stud & Clamp Tube
Position Pair
Stud & Clamp Tube
position Pair
Stud & Clamp Tube
Position Pair
Drain Plug
Air Supply
3 Ports
Equally Spaced
MOUNTING FLANGE MOUNTING
HOLES 12 TOTAL
WATER COOLED OUTER AIR
CYLINDER AIR SUPPLY
WATER COOLED INNER AIR
CYLINDER AIR SUPPLY
WATER COOLED INLET -
3 O'CLOCK & 9 O'CLOCK-
8 ORB PORTS
WATER COOLED OUTLET - 12 O'CLOCK &
6 O'CLOCK- 8 ORB PORTS
Figure 15
Figure 15A