Agency markings*

CE, e-STAR, RCM

Operating temperature

0 to 40 °C (32 to 104 °F)

Storage temperature

Transit temperature

Relative humidity

20 to 90 % (without condensation)

Operating altitude

Up to 3,000 meters (9,843 ft) above sea level, no derating for 35°c (95°F) 
room temperature

Transit altitude

Up to 10,000 meters (32,808 ft) above sea level

Audible noise

9  Glossary

Backup time

Time during which the load can be supplied by the UPS operating on 

battery power.

EBM

Extended Battery Module

Low-battery warning

This is a battery-voltage level indicating that battery power is low and that the 
user must take action before the UPS shuts down.

Load

Devices or equipment connected to the UPS output.

Normal mode

The normal UPS operating mode in which the AC source supplies the UPS which, 

in turn, provides AC power to the connected loads. 

Normal AC source

Normal source of power for the UPS.

Relay contacts

Contacts supplying information to the user in the form of signals.

UPS

Uninterruptible Power Systems.

Содержание 5PXEBM48RTG2

Страница 1: ...5PX Advanced User Guide Copyright 2021 EATON All rights reserved 614 40099 00 5PX1500IRT2UAUG2 5PX2000IRT2UAUG2 5PX2200IRT3UAUG2 5PX3000IRT2UAUG2 5PX3000IRT3UAUG2 5PXEBM48RTG2 5PXEBM72RTG2 5PXEBM72RT...

Страница 2: ...nt a risk of energy or electrical shock or burn from high short circuit current Observe proper precaution Batteries may contain HIGH VOLTAGE and CORROSIVE TOXIC and EXPLOSIVE substances Information ad...

Страница 3: ...nit module optional 15 3 6 Connection with a HotSwap MBP module optional 15 4 Interfaces and Communication 16 4 1 Control panel 16 4 2 LCD description 17 4 3 Display functions 18 4 4 User settings 20...

Страница 4: ...quipment 33 7 Troubleshooting 33 7 1 Typical alarms and faults 34 7 2 Silencing the alarm 36 7 3 Service and support 36 8 Specification and technical characteristics 36 8 1 Power Module model list 36...

Страница 5: ...cy Products are developed according to an eco design approach Substances This product does not contain CFC and HCFC This product does not contain asbestos This product is compliant with regulations on...

Страница 6: ...data destroy unsaved work sessions and damage hardware causing hours of lost productivity and expensive repairs With the Eaton 5PX you can safely eliminate the effects of power disturbances and guard...

Страница 7: ...2x3 4 603x438x85 5 5PX2200IRT2UAUG2 62 2 28 2 23 7x17 2x3 4 603x438x85 5 5PX2200IRT3UAUG2 60 6 27 5 19x17 2x5 1 483x438x129 5PX3000IRT2UAUG2 69 9 31 7 23 7x17 2x3 4 603x438x85 5 5PX3000IRT3UAUG2 68 6...

Страница 8: ...Primary group critical equipment Outlet group programmable outlets USB communication port RS232 communication port Relay output contact Connector for ROO Remote On Off control and RPO Remote Power Of...

Страница 9: ...4 DIN HotSwap external maintenance bypass 6 IEC EFLX8F EFLX8D EFLX12I FlexPDU 8 FR FlexPDU 8 DIN FlexPDU 8 IEC 3 Installation 3 1 Inspecting the equipment If any equipment has been damaged during ship...

Страница 10: ...ent RS232 communication cable USB communication cable Safety instructions Quick start Cable locking systems Rack kit for 19 inch enclosures Two supports for tower position tower feet Communication car...

Страница 11: ...e tower installation with the UPS To install the UPS Place the UPS on a flat stable surface in its final location Always keep 6 or 150 mm of free space behind the UPS rear panel for ventilation If ins...

Страница 12: ...614 40099 00 12 Installation in rack position Follow steps 1 to 4 for module mounting on the rails The rails and necessary hardware are supplied by EATON...

Страница 13: ...e rail on the back of the rack 2 Fix the rail on the front of the rack using the two holes at the bottom 3 Fix the ears plate to the UPS 4 Place the UPS on the rails and fix the ears plate to the top...

Страница 14: ...C power source and the true electrical consumption of the total load 1 For the 5PX 1000 1500 connect the UPS input socket 2 to the AC power source using the cable of the protected equipment For the 5P...

Страница 15: ...affecting the connected loads HotSwap function 1 Connect the input socket 48 on the HotSwap MBP module to the AC power source using the cable 13 supplied 2 Connect the UPS input socket 2 to the UPS In...

Страница 16: ...e goes ON HotSwap MBP module test 1 Set switch 45 to Bypass position and check that the load is still supplied 2 Set switch 45 back to Normal position 4 Interfaces and Communication 4 1 Control panel...

Страница 17: ...fault such as fan blocked or over temperature 4 2 LCD description Load status and measure Equipment status icon Status Message Battery status As default or after 5 minutes of inactivity the LCD displ...

Страница 18: ...se the two middle buttons and to scroll through the menu structure Press the Enter button to select an option Press the ESC button to cancel or return to the previous menu Menu map for Display Functio...

Страница 19: ...put output signals remote signals IPV4 address Event log Event filter Selects faults alarms and or events to display Event list Displays the events stored Reset event list Clears events Fault log Faul...

Страница 20: ...le the buzzer if an alarm occurs Enabled Level 0 8 6 Protected access Enabled Disabled Allow the user to lock the settings modification Password is 0577 Disabled In Out settings Output voltage 200 V 2...

Страница 21: ...ult 90 min Enabled 90min Site Wiring Fault Enabled Disabled Prevents from starting the UPS in case of phase vs neutral wires swapping Disabled Power Off alert Yes No If Enabled activates a confirmatio...

Страница 22: ...y runtime at the expense of long term battery life warranty is also void if set to disable Enable Comm settings Input signals ROO RPO DB9 4 Sets Input signals parameters function delay operation throu...

Страница 23: ...ay 0s 999s Restart Yes No For a proper server shutdown please make sure that the Output OFF delay is long enough Send CMD No Output OFF No OFF delay 0s Restart Yes On battery notice delay 0s 99s Sets...

Страница 24: ...8 V DC max Current 25 mA max Power 1 2 W Pin Signal Direction Function 1 Bat low Output Low Battery Output 2 TxD Output Transmit to external device 3 RxD Input Receive from external device 4 I P SIG I...

Страница 25: ...tion to the same secure UPS monitoring management and sensor capability as the Gigabit Network card Relay MS card provides isolated dry contact Form C relay outputs for UPS status Utility failure Batt...

Страница 26: ...e SELV circuit This circuit must be separated from any hazardous voltage circuits by reinforced insulation The RPO must not be connected to any utility connected circuits Reinforced insulation to the...

Страница 27: ...Description On battery On bat DB9 Pin 8 UPS is in battery mode Low battery Low bat DB9 Pin 1 UPS is in battery mode and has reached the low battery alarm threshold Battery fault Batt fault 1 Relay ou...

Страница 28: ...alarms and restart if necessary 6 Verify that the indicator illuminates solid indicating that the UPS is operating normally and any loads are powered and protected The UPS should be in Normal mode AC...

Страница 29: ...e audible alarm beeps once every 3 seconds This warning is approximate and the actual time to shutdown may vary signifi cantly gracefully shutdown all applications on connected equipment due to immine...

Страница 30: ...ure below 10 C 6 2 Storing the equipment If you store the equipment for a long period recharge the battery every 6 months by connecting the UPS to utility power The internal batteries charge to 90 cap...

Страница 31: ...tteries replace with the same type and number of batteries or battery packs Contact your service representative to order new batteries Proper disposal of batteries is required Refer to your local code...

Страница 32: ...de B Disconnect the battery block by separating the connectors never pull on the wires C Remove the metal protection cover in front of the battery three screws or two screws for 3U models D Pull the p...

Страница 33: ...s is required Refer to your local codes for disposal requirements Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic Do not discard t...

Страница 34: ...nto the Event log Example AC freq in range Alarms are recorded into the Event log and displayed on the LCD status screen with the logo blinking Some alarms may be announced by a beep every 3 seconds E...

Страница 35: ...ected If the condition persists contact your service representative The UPS does not provide the expected backup time The batteries need charging or service Apply utility power for 48 hours to charge...

Страница 36: ...ontact information If repair is required you will be given a Returned Material Authorization RMA number This number must appear on the outside of the package and on the Bill Of Lading if applicable Us...

Страница 37: ...4 22 4 17 6x17 2x3 4 448x438x85 5 5PX2000IRT2UAUG2 61 7 28 0 23 7x17 2x3 4 603x438x85 5 5PX2200IRT2UAUG2 62 2 28 2 23 7x17 2x3 4 603x438x85 5 5PX2200IRT3UAUG2 60 6 27 5 19x17 2x5 1 483x438x129 5PX3000...

Страница 38: ...Number Input connection Input cable 5PX1500IRT2UAUG2 IEC C14 10A Not provided 5PX2000IRT2UAUG2 5PX2200IRT2UAUG2 IEC C20 16A Australia 15A 5PX2200IRT3UAUG2 5PX3000IRT2UAUG2 5PX3000IRT3UAUG2 8 5 Electr...

Страница 39: ...V 9Ah 5PXEBM72RT3UG2 72Vdc 2 x 6 x 12V 9Ah Type Sealed maintenance free valve regulated lead acid with minimum 3 5year float service life at 25 C 77 F Monitoring Advanced monitoring for earlier failur...

Страница 40: ...h the load can be supplied by the UPS operating on battery power EBM Extended Battery Module Low battery warning This is a battery voltage level indicating that battery power is low and that the user...

Отзывы: