6-11 LUBRICATION
All parts that require lubrication have been lubricated
during the assembly with molybdenum disulphide
grease (Eaton Material No. 53701 QB). Over a period
of time, this lubricant may be pushed out of the way or
degrade. Proper lubrication at regular intervals is
essential for maintaining the reliable performance of the
mechanism. Once a year or every 500 operations
whichever comes first, the circuit breaker should be
re-lubricated. The locations shown in Figure 6-1
should be lubricated with a drop of light machine oil.
After lubrication, operate the circuit breaker several
times manually and electrically
Roller bearings are used on the pole shaft, the cam
shaft, the main link and the motor eccentric. These
bearings are packed at the factory with top grade slow
oxidizing grease which normally should be effective
for many years. They should not be disturbed unless
there is definite evidence of sluggishness, dirt or parts
are dismantled for same reason.
If it becomes necessary to disassemble the
mechanism, the bearings and related parts should
be thoroughly cleaned. Remove old grease in a
good grease solvent. Do not use carbon
tetrachloride. They should then be washed in light
machine oil until the cleaner is removed. After the
oil has been drawn off, the bearings should be
packed with Eaton Grease 53701QB or equivalent.
6-12 TROUBLESHOOTING CHART (Continued Next Page)
SYMPTOM
INSPECTION AREA
PROBABLE DEFECTS
Fails To Close
• Control Circuit
• Control Power
(fuse blown or switch off)
• Secondary Disconnects
• Motor Cut-off Switch
(Poor or burned contacts,
Lever not operational)
• Terminals and connectors
(Poor or burned contacts)
• Motor
(Brushes worn or commutator
segment open)
• Closing Springs not charged
• Mechanism
• Pawls
(Slipping or Broken)
• Ratchet Wheel
(Teeth worn or broken)
• Cam Shaft Assembly
(Sluggish or jammed)
• Oscillator
(Reset spring off or broken)
Содержание 380 VCP-Wind
Страница 2: ......
Страница 23: ...I B 70A2580H02 Page 17 Effective November 2012 Figure 5 2 Closing Cam and Trip Linkage ...
Страница 25: ...I B 70A2580H02 Page 19 Effective November 2012 Figure 5 3 Charging Schematic ...
Страница 26: ...Page 20 I B 70A2580H02 Effective November 2012 Figure 5 4 Typical VCP Wind DC Control Schematics ...
Страница 27: ...I B 70A2580H02 Page 21 Effective November 2012 Figure 5 5 Typical VCP Wind AC Control Schematics ...
Страница 47: ...I B 70A2580H02 Page 41 Effective November 2012 Table 7 2 38kV VCP Wind Mini Module Code Pin Position Chart ...
Страница 49: ...I B 70A2580H02 Page 43 Effective November 2012 ...