Figure 7

 

Connection Panel Low er Right Side

Autolite W iring Diagram

Figure 9

 

   Door handle assem bly

Note - For best insert operation the flexible vent
installation should not have any tight bends. Try to
achieve a smooth sw eep to the vertical rise.

SURROUND INSTALLATION

The surround supplied with the insert is adjustable in

height so as to allow for m any installation perim eters.

1.

After the insert is in position, install left and right surround
sides by attaching them  to the two side brackets using the
four 1/4-20 bolts provided. The retainer nuts on the
surround sides m ay be installed at any vertical position to
accom m odate the installation.

2.

Slide the surround top panel between the hopper top and
cover. Push the panel down until the screw holes align
with the side legs. Install the (4) #8 screws provided.
Install power cord into the receptacle on the right side of
the insert. Route cord behind surround leg and out to a
ground plus.

AUTOLITE INSTALLATION INSTRUCTIONS

  The AutoLite System  is factory installed with the only
installation requirem ents being the optional therm ostat.

Wall Thermostat Installation:

  The wall therm ostat is designed to autom atically regulate
the room  tem perature from  the control panel heat setting to
the “Off” setting based upon room  tem perature. Rem em ber
to leave the control panel on the "Medium  or High" position
when utilizing the wall therm ostat feature.

  The following is a step by step procedure for installing the
optional wall therm ostat. Note connection term inals on left
side of unit at rear (

Figure 7

). Use 18/2 therm ostat wire for

the installation.

a.

Unplug heater from  wall outlet and 12VDC power!

b.

Rem ove factory jum p wire and hook up therm ostat
wires to term inals (

Figure 7

).

c.

Locate therm ostat approxim ately 10 to 12 feet from
heater or in area that requires steady tem perature.

d.

Run therm ostat wires from  heater to therm ostat along
wall or under carpet etc. and hook wires to
therm ostat term inals.  On new construction you can,
of course, run wire in the walls before sheet rock or
paneling is done.

e.

Reconnect AC power.

f.

Make sure all wiring is com pleted before plugging the
EASYFIRE Heater back into the wall outlet.

IM PORTANT

 - Any electrical work perform ed on the

EASYFIRE Heater should  be done by qualified personnel.

Remote Control Thermostat Installation:

  The rem ote therm ostat is designed to autom atically
regulate the room  tem perature from  the control panel heat
setting to the “Off” setting based upon room  tem perature
and placem ent of the rem ote therm ostat. Rem em ber to
leave the control panel on the "Medium  or High" position
when utilizing the wall therm ostat feature.

  The following is a step by step procedure for installing the
optional rem ote therm ostat. Note connection term inals on
rear of unit (

Figure 7

).

a.

Unplug heater from  wall outlet and 12VDC power!

b.

Mount m illivolt style rem ote receiver box to rear of
stove using double-sided tape.

b.

Rem ove factory jum p wire and hook up therm ostat
wires to term inals (

Figure 7

).

d.

Reconnect AC power and follow instructions with
rem ote therm ostat regarding set up.

IM PORTANT

 - Any electrical work perform ed on the

 EASYFIRE Heater should  be done by qualified personnel.

DOOR HANDLE ASSEMBLY

The door handle and latch m ust be assem bled and
adjusted prior to the operation of the stove.

1. Position handle assem bly through door and secure with

collar by sliding over shaft and tightening with allen
wrench provided.

2. Position latch on end of shaft with flat facing allen screw.

Depending on gasket, shaft will protrude approx. 1/4"
through back of latch collar. Snug allen screw.

3. To adjust door, close and turn handle so latch contacts

striker. Door gasket m ust contact firm ly against front face
of unit. This can be checked by closing against a piece of 
paper. Firm ly tug on paper, if it m oves with solid
resistance the door is properly adjusted.

Содержание EF4001B AutoLite

Страница 1: ...n More frequent cleaning may be required due to fuel quality excessive lint from carpeting bedding material etc It is imperative that control compartments burn pot and circulat ing air passageways of...

Страница 2: ...lation instructions OUTSIDE COMBUSTION AIR IS MANDATORY IN MOBILE OR MODULAR HOME INSTALLATIONS SEE SECTION ON OUTSIDE AIR INSTALLATION CAUTION DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM IN...

Страница 3: ...earth passing damper and continuing to the top of the chimney If the total vent length is longer than 10 Feet install 4 vent from that point to top of chimney Figure 6 5 Pack fiberglass insulation aro...

Страница 4: ...erature d Run thermostat wires from heater to thermostat along wall or under carpet etc and hook wires to thermostat terminals On new construction you can of course run wire in the walls before sheet...

Страница 5: ...passage through a wall or partition of combustible construction is desired the installation shall conform the CAN CSA B365 3 Maintain an effective vapour barrier at the location where the chimney or...

Страница 6: ...e your cleaning and maintenance time Store pellets in a clean dry area Do not use pellets that have been damp or have a moisture level above 5 The quality of pellet fuel varies from brand to brand Thi...

Страница 7: ...CAUTION Moving parts may cause injury DO NOT operate with rear cover removed WARNING Risk of electrical shock disconnect all AC DC power before servicing ALWAYS TURN YOUR Heater OFF LET IT COOL BEFORE...

Страница 8: ...sually means that the air flow has been reduced Check the Fire Pot air intake holes to be sure they are clear Check to see if Fire Pot was properly seated in pot tray Check to see if the manifold may...

Страница 9: ...opper lid must be closed before operating unit Maintain hopper seal in good condition DO NOT OVERFILL HOPPER The EASYFIRE will hold about 35 lbs to 50 lbs of pellets depending on hopper height Open th...

Страница 10: ...croprocessor is automatically adjusting the feed and air based on temperature This means the pellet feed rate and flame height will change accordingly based on quality of pellet and heat loss of dwell...

Страница 11: ...th a soft cloth and non abrasive cleaner 6 Cleaning Polishing Gold Plated Parts Gold is a soft metal and therefore a fragile surface Prior to the first burn it is important to use W index or comparabl...

Страница 12: ...ssive ash and clogging particularly the vent cap Remove the clean out cap on the tee and make sure that ash has not blocked the exhaust air flow This automatic shut down in case of flue clogging is a...

Страница 13: ...RD V2 1 6A 110080 MAIN FUSE 1 AMP 6B 110510 AUTOLITE FUSE 5 AMP 7 200549 HEAT EXCHANGE COVER 8 110456 ASH DRAWER FIBER ROPE GASKET 9 110451 ASH DRAWER KNOB 10 120117 IGNITOR 200W 11 300512 BURN POT AL...

Отзывы: