background image

3

Figure 3

Figure 4

Figure 5

Figure 6

3.

If the hearth and fireplace floor are not at the sam e
elevation, leveling legs m ay be installed on the rear of the
unit 

(Figure 4)

 for distances of up to 1". For larger

distances shim m ing m ay be used using a non-com bustible
m aterial. A Hearth Base Support is available from  your
dealer for installations where the hearth is below the
fireplace opening 

(Figure 5)

.

NOTE: THE INSERT W EIGHT IS SUBSTANTIAULLY
FRONT HEAVY AND IF NOT FULLY SUPPORTED IT
COULD FALL FORW ARD.

4.

Install vent system  into existing chim ney by using 3" flex
from  left side of hearth, passing dam per and continuing to
the top of the chim ney. If the total vent length is longer than
10 Feet, install Ø4" vent from  that point to top of chim ney

(Figure 6)

.

5.

Pack fiberglass insulation around the vent pipe and
com bustion air duct. Install a flashing cover over
chim ney. Secure flashing and seal as required. Install
listed vent cap and secure.

6.

Measure fireplace opening and adjust hopper top to the
required level allowing for installation clearance. This is
accom plished by rem oving the four #8 screws on the sides
and rear of unit and raising the top by 1" increm ents until
desired height and reinstalling screws 

(Figure 4)

.

7.

Slide insert into fireplace and center. Level as required,
then secure vent to outlet on left side of insert. Connect
com bustion air duct and secure.

Содержание EF4001B AutoLite

Страница 1: ...n More frequent cleaning may be required due to fuel quality excessive lint from carpeting bedding material etc It is imperative that control compartments burn pot and circulat ing air passageways of...

Страница 2: ...lation instructions OUTSIDE COMBUSTION AIR IS MANDATORY IN MOBILE OR MODULAR HOME INSTALLATIONS SEE SECTION ON OUTSIDE AIR INSTALLATION CAUTION DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM IN...

Страница 3: ...earth passing damper and continuing to the top of the chimney If the total vent length is longer than 10 Feet install 4 vent from that point to top of chimney Figure 6 5 Pack fiberglass insulation aro...

Страница 4: ...erature d Run thermostat wires from heater to thermostat along wall or under carpet etc and hook wires to thermostat terminals On new construction you can of course run wire in the walls before sheet...

Страница 5: ...passage through a wall or partition of combustible construction is desired the installation shall conform the CAN CSA B365 3 Maintain an effective vapour barrier at the location where the chimney or...

Страница 6: ...e your cleaning and maintenance time Store pellets in a clean dry area Do not use pellets that have been damp or have a moisture level above 5 The quality of pellet fuel varies from brand to brand Thi...

Страница 7: ...CAUTION Moving parts may cause injury DO NOT operate with rear cover removed WARNING Risk of electrical shock disconnect all AC DC power before servicing ALWAYS TURN YOUR Heater OFF LET IT COOL BEFORE...

Страница 8: ...sually means that the air flow has been reduced Check the Fire Pot air intake holes to be sure they are clear Check to see if Fire Pot was properly seated in pot tray Check to see if the manifold may...

Страница 9: ...opper lid must be closed before operating unit Maintain hopper seal in good condition DO NOT OVERFILL HOPPER The EASYFIRE will hold about 35 lbs to 50 lbs of pellets depending on hopper height Open th...

Страница 10: ...croprocessor is automatically adjusting the feed and air based on temperature This means the pellet feed rate and flame height will change accordingly based on quality of pellet and heat loss of dwell...

Страница 11: ...th a soft cloth and non abrasive cleaner 6 Cleaning Polishing Gold Plated Parts Gold is a soft metal and therefore a fragile surface Prior to the first burn it is important to use W index or comparabl...

Страница 12: ...ssive ash and clogging particularly the vent cap Remove the clean out cap on the tee and make sure that ash has not blocked the exhaust air flow This automatic shut down in case of flue clogging is a...

Страница 13: ...RD V2 1 6A 110080 MAIN FUSE 1 AMP 6B 110510 AUTOLITE FUSE 5 AMP 7 200549 HEAT EXCHANGE COVER 8 110456 ASH DRAWER FIBER ROPE GASKET 9 110451 ASH DRAWER KNOB 10 120117 IGNITOR 200W 11 300512 BURN POT AL...

Отзывы: