background image

10

Figure 14

Note: Caution m ust be taken when installing burn pot
or operating door not to dam age ceram ic glass. Do not
attem pt to operate heater if glass becom es dam aged in
any w ay!

2. Control Functions:

  Control functions on the Easyfire

are as follows:  OFF, FAN, LOW , MEDIUM, HIGH, CLEAN.
Here is how each function works:

A.

W hen the Control is set to 

FAN

, a tim er is activated

and you will have about ten (10) m inutes to get the
pellets lit and reach a m inim um  tem perature.  

Should the pellets not light in the 10 m inutes sim ply turn
the knob to 

OFF

 and begin again.  This will give you

another 10 m inutes to get the pellets lit.  The reason for
the tim er function is so that the heater will autom atically
shut down if the fire goes out.  Pellets do not feed in the
FAN position.

B.

In the 

LOW

 position, the EASYFIRE will be feeding

approxim ately 1 to 1½ lbs. of pellets per hour and the
flam e will fluctuate between 1" and 6" in height.

C.

In the 

M EDIUM

 position the EASYFIRE will be

feeding approxim ately three (3) pounds of pellets per
hour and the flam e will fluctuate between 3" and 8" of
fire.

D.

In the 

HIGH

 position the EASYFIRE will be feeding

approxim ately 4 lbs. per hour and the flam e will
fluctuate between 3" and a full flam e.  The fan speed
will increase accordingly as the heater autom atically
adjusts itself based on tem perature inside the heater
(see G  below).

E.

The 

CLEAN

 position is to be used only when the

heater is not burning and you wish to clean out the
accum ulated ash in the front of the fire area. See

CLEAN OUT

 section of m aintenance instructions.

F.

After the heater is running for several hours and you
wish to turn it off sim ply turn the knob to 

OFF

The

heater w ill continue running until it cools dow n
and then will automatically shut itself dow n

.

G.

REM EM BER:

  Each feed position will fluctuate

because the m icroprocessor is autom atically
adjusting the feed and air based on tem perature. This
m eans the pellet feed rate and flam e height will
change accordingly based on quality of pellet and
heat loss of dwelling.

MAINTENANCE PROCEDURE

CAUTION:

  Moving parts m ay cause injury, DO NOT

operate with rear cover rem oved.

W ARNING:

  Risk of electrical shock, disconnect all power

before servicing.

ALW AYS TURN YOUR Heater OFF & LET IT COOL
BEFORE CLEANING.

Your EASYFIRE Pellet Heater requires routine

m aintenance for m axim um  perform ance and is m andatory
for the warranty to rem ain in effect.

The following procedures should be studied carefully and

perform ed regularly as indicated:

1. Fly-ash:

  Som e ash will accum ulate in the heat

exchanger, Fire Pot and flue and should be cleaned out
on a regular basis for best efficiency and safety.  W hen
the heater is shut down and cold, you should:

a.

Open door and rem ove Heat Exchanger Cover. To
rem ove, sim ply slide up and out from  retaining angle
bracket (

Figure 12

). Clean one side at a tim e. W ith

one slide cover rem oved, 

leave door open 

and turn

control knob to the 

"CLEAN"

 position. Let heater run

until ash in Fire Pot area is vacuum ed out by heater
fan. Turn off and replace cover. Rem ove rem aining
cover and repeat procedure for the other side.  The
vent pipe should be cleaned out after this procedure.
Rem ove the clean-out port cover 

(Figure 13)

 and

vacuum  as required. 

b.

Rem ove Fire Pot by lifting up and out, it m ay be
brushed out or vacuum ed. Fire Pot should be
cleaned daily. Make sure holes in pot are not
clogged.  The area around and below the pot should
be checked every five or six days depending on how
m any hours a day you are burning your heater and
the quality of the pellets being burned.  (After a few
days you will be able to determ ine the frequency
needed for clean out.)

The im portant thing to rem em ber is that excessive Fly-

ash accum ulation will affect the efficiency of the burn.

c.

Scrape pellet feed chute with putty knife to rem ove
hardened m aterial on which sawdust can
accum ulate.

Содержание EF4001B AutoLite

Страница 1: ...n More frequent cleaning may be required due to fuel quality excessive lint from carpeting bedding material etc It is imperative that control compartments burn pot and circulat ing air passageways of...

Страница 2: ...lation instructions OUTSIDE COMBUSTION AIR IS MANDATORY IN MOBILE OR MODULAR HOME INSTALLATIONS SEE SECTION ON OUTSIDE AIR INSTALLATION CAUTION DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM IN...

Страница 3: ...earth passing damper and continuing to the top of the chimney If the total vent length is longer than 10 Feet install 4 vent from that point to top of chimney Figure 6 5 Pack fiberglass insulation aro...

Страница 4: ...erature d Run thermostat wires from heater to thermostat along wall or under carpet etc and hook wires to thermostat terminals On new construction you can of course run wire in the walls before sheet...

Страница 5: ...passage through a wall or partition of combustible construction is desired the installation shall conform the CAN CSA B365 3 Maintain an effective vapour barrier at the location where the chimney or...

Страница 6: ...e your cleaning and maintenance time Store pellets in a clean dry area Do not use pellets that have been damp or have a moisture level above 5 The quality of pellet fuel varies from brand to brand Thi...

Страница 7: ...CAUTION Moving parts may cause injury DO NOT operate with rear cover removed WARNING Risk of electrical shock disconnect all AC DC power before servicing ALWAYS TURN YOUR Heater OFF LET IT COOL BEFORE...

Страница 8: ...sually means that the air flow has been reduced Check the Fire Pot air intake holes to be sure they are clear Check to see if Fire Pot was properly seated in pot tray Check to see if the manifold may...

Страница 9: ...opper lid must be closed before operating unit Maintain hopper seal in good condition DO NOT OVERFILL HOPPER The EASYFIRE will hold about 35 lbs to 50 lbs of pellets depending on hopper height Open th...

Страница 10: ...croprocessor is automatically adjusting the feed and air based on temperature This means the pellet feed rate and flame height will change accordingly based on quality of pellet and heat loss of dwell...

Страница 11: ...th a soft cloth and non abrasive cleaner 6 Cleaning Polishing Gold Plated Parts Gold is a soft metal and therefore a fragile surface Prior to the first burn it is important to use W index or comparabl...

Страница 12: ...ssive ash and clogging particularly the vent cap Remove the clean out cap on the tee and make sure that ash has not blocked the exhaust air flow This automatic shut down in case of flue clogging is a...

Страница 13: ...RD V2 1 6A 110080 MAIN FUSE 1 AMP 6B 110510 AUTOLITE FUSE 5 AMP 7 200549 HEAT EXCHANGE COVER 8 110456 ASH DRAWER FIBER ROPE GASKET 9 110451 ASH DRAWER KNOB 10 120117 IGNITOR 200W 11 300512 BURN POT AL...

Отзывы: