background image

 

Outside Air Kit 

99200139

 

 

Page 1 of 2 

17601452 - 2/21/20 

© Travis Industries, Inc.  

Compatibility:

    

• All Lopi Wood Stoves 

• Foxfire AGP

 

 

• Deerfield AGP

 

Packing List:

    

 

Outside Air Duct Assembly 

 

Hood (includes rodent screen) 

 Flashing 

 

3” Duct (4’ long) 

 Cover 

Plate 

 

 

(2) Hose Clamps 

 

(2) #8 Screws  
(for securing air duct assembly to stoves with legs). 

 

(2) 1” Wood Screws, (2) 1-1/2” Wood Screws, (2) Drywall Anchors (for 
securing the hood and flashing) 
 

Cover Plate (Required for Lopi Answer Wood Stove) 

When using outside air with wood stoves the cover plate may be required to insure combustion air is drawn from below.  
See the table and instructions below for details. 

Answer Cover Plate Installation 

Remove the air control stop on the stove.

Remove the bridge and plugs from the front of 

the cover plate.

Re-attach the bridge to complete the cover plate installation.

Attach the air control stop and cover plate as 

shown above.  HINT: Place one screw through the 

cover plate and air control stop, and while holding 

them together, slide the components into place 

and tighten the screws to secure.

 

 

Outside Air Knock-Out (Must be removed on the Lopi Answer Wood Stove) 

On the Lopi Answer remove the forward knock-out on the bottom of the stove. 

Outside Air Knock-Out

Rear Blower Knock-Outs

FRONT OF STOVE

 

 