 WARNING!

Explosion and fire hazard!
Improperly handling the humidifier may cause an explosion or a 

fire.

 

− Keep the humidifier away from water, other liquids, open 

flames, and hot surfaces.

 

− Do not cover the humidifier or the power plug with items or 

clothing.

 

− Maintain a distance of at least 2 inches from highly flammable 

materials.

 

− Do not expose the humidifier to excessive heat, such as direct 

sunlight, fire or the like.

 

− Only use the humidifier using the supplied accessories. 

NOTICE!

Risk of damage!
Improperly handling the humidifier may cause it to become damaged.

 

− DO NOT carry water tank by handle when it is filled with water. It is 

advisable to carry filled water tank with two hands.

 

− DO NOT operate outdoors. This humidifier is intended for indoor 

use only. Always have water in the tank when operating the unit.

 

− Use only clean, cool tap water to fill the tank. Filtered or distilled 

water is recommended to avoid white dust if tap water is too 

hard. DO NOT use hot water.

 

− DO NOT pour water in any openings other than the water tank.

 

− Be sure that the water tank cap is firmly tightened. Always have 

the mist direction nozzle and the mist chamber in place while the 

unit is operating. Rotate the mist direction nozzle so it aims away 

from children, walls, furniture, and electrical appliances.

 

− Unplug the humidifier when not in use and whenever you clean 

or move the humidifier.

 

− Always place the humidifier on a smooth, flat, lint free, non-

metallic, waterproof, level surface, and away from direct sunlight. 

Keep the power cord away from heated surfaces and areas where 

it could be walked on or tripped over. DO NOT let the cord hang 

over the edge of a table or counter.

 

− DO NOT add medication of any type into the nozzle, base or water 

tank. Do not cover any openings on the humidifier or insert 

objects into any openings.

 

− The humidifier should not be left unattended in a closed room as 

the air could become saturated and leave condensation on walls 

or furniture. Leave room door partly open.

 

− The humidifier requires daily and weekly cleaning to operate 

appropriately. Refer to cleaning instructions.

 

− When cleaning the inside of the unit keep water away from the 

air outlet / fan vent. The exterior may be wiped with a damp 

cloth, except the electrical controls, only when the unit is off and 

unplugged.

 

− NEVER use detergents, gasoline, glass cleaner, furniture polish, 

paint thinner or other household solvents to clean any part of 

the humidifier. Always use a few drops of bleach with water to 

clean humidifier. Detergent film dissolved in the water supply can 

interfere with the output of the unit.

 

− Do not tilt or tip the unit or attempt to empty or fill it while it is in 

operation.

 

− Do not touch hot surfaces. Use handles or knobs.

 

− Use the humidifier only as described in this manual. The use of 

accessory attachments not recommended by the manufacturer 

may cause damage to the humidifier or personal injuries.

 

− Do not overfill the water tank.

 

− Always fill water tank first, then plug the cord into the wall outlet. 

To disconnect, always turn OFF first, then unplug from wall outlet.

 

− Do not let cord hang over edge of counter or touch hot surfaces. 

 

 

Содержание HF3102A-UL

Страница 1: ...of packaging 5 Note Humidifier is pre assembled and ready to use 5 General information 6 Read and SAVE these instructions 6 Proper use 6 Explanation of symbols 6 Safety 7 Explanation of instructions...

Страница 2: ...r light 8 Medicine cup 9 Water tank 10 Water tank cap 11 Mist channel 12 Vapor pad Piezas principales 1 C mara de vapor 2 Base del humidificador 3 Sensor del nivel de agua 4 Patas antideslizantes 5 Re...

Страница 3: ...5 Components Contents of packaging Note Humidifier is pre assembled and ready to use Humidifier base Water tank Mist chamber Medicine cup Instruction manual...

Страница 4: ...ndesired operation Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equip...

Страница 5: ...wet hands Do not abuse the power cord Never carry the humidifier by the power cord or pull the power cord to disconnect the outlet plug from an outlet instead grasp the outlet plug and pull to disconn...

Страница 6: ...surface and away from direct sunlight Keep the power cord away from heated surfaces and areas where it could be walked on or tripped over DO NOTlet the cord hang over the edge of a table or counter D...

Страница 7: ...everse the plug If it still does not fit contact a qualified electrician Do not attempt to modify the plug in any way Electric power Iftheelectriccircuitisoverloadedwithotherappliances yourhumidifier...

Страница 8: ...ever if you have to use an extension cord the extension cord should be rated for 13 amps 125V 1625 watts The power supply cord must be arranged so that it will not drape over the countertop or tableto...

Страница 9: ...the mist channel p 4 fig B 11 You can mix and match any oil scents you would like 1 Place about 3 drops of desired scent on the aroma pad located in the aroma tray p 4 fig C 12 2 Push the aroma pad i...

Страница 10: ...to reduce the risk of bacterial growth and also to remove any scale residue to maintain good operational performance Follow the procedures below for healthy maintenance of your Warm mist humidifier C...

Страница 11: ...everal days being sure to dry all parts Allow the water tank to thoroughly air dry before storage DO NOT store with water inside any part of the humidifier 2 Leave tank cap partially loosened during s...

Страница 12: ...ea y GUARDE estas instrucciones 24 Uso correcto 24 Significado de los s mbolos 24 Seguridad 25 Explicaci n de las instrucciones 25 Informaci n general de seguridad 26 Primer uso 30 Comprobaci n del hu...

Страница 13: ...cias que puedan causar un funcionamiento no deseado Advertencia Los cambios o modificaciones a esta unidad no aprobados expresamente por la parte responsable del cumplimiento podr an anular la autorid...

Страница 14: ...el cable de alimentaci n No transporte nunca el humidificador por el cable de alimentaci n ni tire de este para desenchufarlo del tomacorriente agarre el enchufe y j lelo para desconectarlo Mantenga...

Страница 15: ...sol Mantenga el cable de alimentaci n alejado de las superficies calientes y donde pueda pisarse o causar tropezones NO permita que el cable cuelgue del borde de una mesa o mostrador NO agregue ning...

Страница 16: ...arizado unaclavijaes m sanchaquelaotra Comomedidadeseguridadparareducirel riesgodedescargael ctrica esteenchufeest dise adoparaentrar Seguridad 31 enuntomacorrientepolarizadoenunsolosentido Sielenchuf...

Страница 17: ...ersonales resultantes de enredarse o tropezar con un cable m s largo Para evitar una sobrecarga del circuito al usar este humidificador no haga funcionar el producto con otro aparato de alto voltaje e...

Страница 18: ...ser forzado hacia abajo por la corriente de aire Cambie el humidificador de sitio o reduzca la salida de los otros aparatos de ventilaci n de la habitaci n Uso de aceites esenciales Se pueden utiliza...

Страница 19: ...eza y mantenimiento Los humidificadores port tiles requieren una limpieza peri dica a fin de reducir el riesgo de crecimiento bacteriano y tambi n para eliminar los restos de cal a fin de mantener un...

Страница 20: ...bserva la acumulaci n de impure zas o detecta olores desagradables Repita los pasos del 1 al 4 que se mencionan arriba Mantenimiento y almacenamiento de final de temporada 1 Siga el procedimiento ante...

Страница 21: ...n del embalaje Elimine el embalaje de forma respetuosa con el medio ambiente Eliminaci n del producto Si el producto deja de funcionar aseg rese de eliminarlo de forma respetuosa con el medio ambiente...

Отзывы: