12
Form E-564
Eastman
®
6. Loosen the Jam Nut and adjust the Stop Set
Screw to get the desired position.
Stop
Set Screw
Jam Nut
7. After adjusting position with the Stop Set Screw,
tighten the Jam Nut to lock the stop position of
the
Sharpener.
9. Push down on the Presser Foot Assembly to
remove the Guide Shaft Spacer.
Knife
Guide Shaft
Spacer
54-28797
8. Slide the Sharpener back to the left.
Sharpener
Home
Position
WARNING
Sharp Knife is exposed. When handling the
Presser Foot, use caution.
10. Close the front tool head cover and Turn the Ma-
chine Power, Blower and Air back on for opera-
tion.
4. Slide the Sharpener to the right as far as it will
go without bending the blade.
5. Rotate the Presser Foot so the Angled surface
on the Knife is parallel with the sharpening pads.
WARNING
Sharp Knife is exposed. When handling the
Presser Foot, use caution.
Sharpener
Angled
Surface
KNIFE BOTTOM
VIEW
Sharpening
Pad
NOTE: Sharpening Pads should make contact
with the angled surface on the knife. Should
not deflect blade.