2.4.5 Constant Current Switch to Constant Voltage Measurement Mode
The constant current voltage measurement mode is to prevent damage to the source under
test due to overcurrent discharge. In this mode, when the source to be tested cannot output
the current value set by the load, it will automatically switch from the constant current mode
to the constant voltage mode.
Operation instructions: 1. Press the [CH] key to select the operation channel; 2. Select the
operation item by rotating the knob; 3. Set the parameters. Press [Enter] to enter the edit
mode, use the arrow keys to select the corresponding number of digits, then adjust the value
by turning the knob, [Enter], [Shift] + [
▶
] (Esc) to exit editing; 4. Press the corresponding
[On1], [On2] startup mode.
Fig 2.4.5 Constant Current Switch to Constant Voltage Measurement Mode
2.4.6 Constant Resistance Switch to Constant Voltage Measurement
Mode
The constant resistance voltage measurement mode is to prevent damage to the source to be
tested due to overcurrent discharge. In this mode, when the source to be tested cannot output
enough current to maintain the set resistance, the load will change from constant resistance
mode to constant voltage mode.
Operation instructions: 1. Press the [CH] key to select the operation channel; 2. Select the
operation item by rotating the knob; 3. Set the parameters. Press [Enter] to enter the edit
mode, use the arrow keys to select the corresponding number of digits, then adjust the value
by turning the knob, [Enter], [Shift] + [
▶
] (Esc) to exit editing; 4. Press the corresponding
[On1], [On2] startup mode.