Fig 2.5.2 Dynamic Test Interface
2.6 List Testing Mode
The list test function can conveniently test the working condition of the source to be tested
under different load conditions, which is beneficial to the automatic test of the production
line. By pre-setting the steps of the list test, the test steps and test parameters of the source to
be tested can be edited into a list and a series of tests can be completed in order. Specific
setting parameters include: setting the number of steps, stepping mode, cycle switch, load
mode of each step, load size, delay time, comparison switch, upper limit value, lower limit
value.
In the list test interface, press [Shift] + [
◀
] (Menu) to enter the list menu interface, adjust the
knob to select the corresponding option, press [Enter] to enter the corresponding submenu.
Fig 2.6 List Menu Interface
The setup interface and test interface are shown in Figure 2.6.1 and 2.6.2 respectively, and the test
end test result interface is shown in 2.6.3.
List test setting interface operation instructions: 1. Select the operation item by rotating the knob; 2.
Edit the parameter by switching the direction key to the editing state, select the previous page or the next
page with the direction key and press [Enter] to proceed. Page turning operation, press the arrow key to
save and press [Enter] to enter the list test parameter saving interface; 3. In the editing state, press the
[Enter] key to switch the setting option; 4. Edit the digital parameter in the state, press [Enter]
】
Enter the
edit mode, use the arrow keys to select the corresponding number of digits, then rotate the knob to adjust
the value, [Enter] or [Shift] + [
▶
] (Esc) to exit editing; 5. Press [Shift] + [
▶
] ( Esc) returns to the
previous interface;