2.10
Short Circuit Test Operation
The load can simulate a short circuit at the input. In the short-circuit test, the actual current
value consumed by the load short-circuit depends on the maximum output of the power
supply.
Operation instructions: 1. Press the [CH] key to select the operation channel; 2. Select the
operation item by rotating the knob; 3. Set the parameters. Press [Enter] to enter the edit
mode, use the arrow keys to select the corresponding number of digits, then adjust the value
by turning the knob, [Enter] or [Shift] + [
▶
] (Esc) to exit editing; 4. Press the corresponding
[On1], [On2] Start or disable mode.
Fig 2.10 Short Circuit Test Interface
2.11 Protection Function
The load provides overcurrent, overvoltage, overpower, overtemperature, and polarity
reverse protection (the message is based on the physical map).
2.12 Trigger Function
The load has a trigger function, which is mainly used in dynamic and list tests to initiate the
next conversion. The load supports three trigger modes: 1. Manual (triggered by the [Trigger]