/ Programmable DC Electronic Load - User Manual
Fig. 7-1-1 Basic Electrical Parameters
Fig. 7-1-2 Capacity AH and Energy WH Recorded from Last Measurement
The recording time consists of hours on the first line, minutes on the second line and
seconds on the third line.
Fig. 7-1-3 Time Value from Last Record
When the channel is activated, users can use the knob and arrow buttons [▲ ▼◄ ►] to
switch the display among basic electrical parameters (voltage, current, power), ampere-hour,
watt-hour, the time of the last battery measurement and the resistance value.
Fig. 7-1-4 Display of Various Parameters When the Channel Is Activated
Fig. 7-1-5 Display of Resistance Value
7.2. Parameter Editing
Parameters cannot be edited while the channel is activated; editing is only possible when the
channel is deactivated.
Press the [ENT] button to enter the parameter setting interface, and select the parameter to be
edited using the knob or arrow buttons. After the selection, press the [ENT] button again to edit