Isokern Maximus Linear See-Thru Installation
6)
The fireplaces come with an 8”-thick damper beam assembly, a component group that is to be assembled on top of the
firebox side walls and steel angle iron (no steel angle iron in 48” model). The damper beam assembly consists of long
lintel pieces and two (2) short damper end blocks. The lintels will be equal to the width of the fireplace model that they
serve. These components both sit on their narrow base so that their beveled face points down and into the firebox
interior
(Figure 12).
The damper end blocks are designed to sit on the firebox side wall between the front lintel and the back lintel. Each of
the damper end blocks are designed for a specific side of the unit. When properly set, the vertical face of each damper
end block will be flush with the outside face of the firebox side wall
(Figure 12)
.
Begin by setting the rear Damper Beam components into place. Next, set the Damper End Blocks into place atop the
sidewalls in a bed of Earthcore Adhesive. Be sure to apply Earthcore Adhesive to the contact surfaces of each Damper
End Block component where it will meet the front and back damper beam lintel components. Next, set the front
Damper Beams into place.
NOTE:
Be sure to apply Earthcore Adhesive to contact surfaces between all Isokern components
Magnum Damper
End Block; Left:
M94L
Magnum Damper
End Block; Right:
M94R
Damper Beams (Rear):
48”: Part# 70
72”: Part# 69, 83
96”: Part# 68 (qty 2), 167
120”: Part# 70, 69, 74
Damper Beams (Rear):
48”: Part# 70
72”: Part# 69, 83
96”: Part# 68 (qty 2), 167
120”: Part# 70, 69, 74
FIGURE 12