Earth Stove BV4000C-2 Скачать руководство пользователя страница 9

INSTALLATION 

 

PAGE 9 

CATALYTIC TEMPERATURE PROBE

 

Install temperature probe prior to installing insert

.  

To install the

 Catalytic Temperature Probe

 locate the plug 

on the top, right-hand side of the bypass control rod. Re-
move the plug, install the sleeve, and place probe in sleeve. 
It may be necessary to bend the flange on the plug so it 
won't interfere with the probe temperature indicator. 
 

 

 

The Catalytic Temperature Probe is provided so you can 
monitor the temperature of your Catalytic Combustor. Once 
you have established a fire and the Catalytic Temperature 
Probe indicates the temperature of your Catalytic Combus-
tor is between 500° - 600° F (approximately 20 - 25 min-
utes) close the Bypass Damper Control. Depending on the 
type and size of the fuel load as well as the length of time 
the stove has been burning, your Catalytic Combustor 
should operate between 1000 - 1800° F. 
 

POWER CORD CHANGEOVER 

The power cord which is positioned on the left side of the 
insert (as viewed while facing unit), can be relocated to 
the right side, using an optional 

Cord Changeover Kit 

(See 

Cat. No. 14M73, on page 29). 
 

INSTALLATION STEPS

 

1. Remove all ashes from the fireplace. 
2. Remove all materials inside the insert and set them 

aside. 

3. 

Remove the three-piece surround assembly (pur-
chased separately) and attach insulation material pro-
vided using a nonflammable adhesive (i.e. RTV High 
Temperature Silicone, rated 570

°

 F). 

4. Use a large piece of cardboard or other protective 

material and place it in front of the fireplace to protect 
floor or carpet during installation. 

5. Remove the insert from its wood pallet by removing 

the screws. 

6.  Prepare chimney connection system as specified 

for masonry or factory built fireplaces. 

7.  Set the insert on the protective cardboard laid out in 

front of the fireplace centered in front of the fire-
place opening.  

8.  (Masonry Fireplace) Slide insert into the fireplace 

far enough to attach the starter pipe or positive flue 
connection (a minimum of a 6" starter pipe extend-
ing past the header is required). See * note. 

9.  (Factory Built Fireplace) Slide insert into the fire-

place far enough to attach connector to flue outlet. 
See * note. 

10. Offsets can be handled using an offset adapter (it 

aligns starter pipe with flue. See 

Offset Adapter

page 25 for ordering information). Do not push in-
sert in completely until surround assembly is in-
stalled. Care should be used to ensure that this ad-
justable connector is oriented so it does not angle 
downhill when positioned on the flue outlet on top of 
insert. 

 
 
 
 
 
 

 

 
 
 

 

Inspection Plug 

Insert sleeve (small silver part) 
and probe into this hole. 

WRONG 

CORRECT – Level 
or even. Slightly up 
at the outbound 
end is better. 

WRONG – This may 
produce a problem 
of smoking during 
refueling, or poor 
chimney draw. 

CORRECT 

Once offset is leveled and aligned to the vent 
pipe, the offset must be sealed with high tem-
perature sealant. 

f i r e - p a r t s . c o m

Содержание BV4000C-2

Страница 1: ...RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE EPA CERTIFIED CATALYTIC WOOD BURNING FIREPLACE INSERT THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER READ ENTIRE MANUAL THOROUGHLY BEFORE INS...

Страница 2: ...tor glows you are overfiring Overfiring this ap pliance could cause a house fire Overfiring is a condition where the appliance is operated at temperatures above its design capabilities see Overfiring...

Страница 3: ...TIONS ON THE PURCHASE OF YOUR NEW WOOD BURNING FIREPLACE INSERT MANUFACTURED BY LENNOX HEARTH PROD UCTS When you purchased your new insert you joined the ranks of thousands of concerned individuals wh...

Страница 4: ...e partment for requirements in your area IMPORTANT THIS APPLIANCE IS NOT APPROVED FOR INSTALLATION INTO A MANUFACTURED MO BILE HOME IN CANADA OR IN THE USA FLOOR PROTECTION This appliance requires a h...

Страница 5: ...FOR COMBUSTION In well insulated and weather tight homes it may be diffi cult to establish a good draft up your chimney The poor draft is caused by a shortage of air in the house To pro vide the neede...

Страница 6: ...IFE Factory Built Fireplace Installation MASONRY FIREPLACES Note Measure fireplace size to make certain the insert will fit before considering the installation This appliance is approved for installat...

Страница 7: ...ue size should be no more than 3 three times the cross sec tional area of the size of the fireplace insert flue collar In this case that would be no larger than a 10 inch 254 mm diameter stack area ap...

Страница 8: ...Note Measure fireplace size to make certain the in sert will fit before considering the installation Minimum size required for fireplace firebox recessed area into fireplace Height 21 533 mm Width 22...

Страница 9: ...mmable adhesive i e RTV High Temperature Silicone rated 570 F 4 Use a large piece of cardboard or other protective material and place it in front of the fireplace to protect floor or carpet during ins...

Страница 10: ...r attach the positive flue connection to the insert See Note SURROUND ASSEMBLY PURCHASED SEPARATELY NOTE Do not face seal over chimney cooling air system on superior brand or any brand fireplace which...

Страница 11: ...open posi tion If this is not possible it will be necessary to remove the damper Installation into a masonry fireplace re quires as a minimum of a flue extension past the header This can be accomplish...

Страница 12: ...ill affect the control setting The same con trol settings in a variety of installations will produce different results You will need to try different settings so you can learn how much heat to expect...

Страница 13: ...handle to the 6 00 position See illustration above GLASS The Glass is a super heat resistant ceramic that with stands continuous temperatures up to 1390 F This tem perature is well beyond the tempera...

Страница 14: ...ring the refueling we recommend that the stove be refired for about 10 minutes with the bypass open to ensure a good draw is established and that the catalyst reaches 600 F The refiring will ensure su...

Страница 15: ...urned off by rotating the rheostat dial counterclockwise until it clicks CAUTION BURNING THE INSERT AT A HIGH BURN RATE FOR EXTENDED PERIODS WITHOUT RUN NING THE BLOWERS CAN CAUSE EXCESSIVE TEMPERATUR...

Страница 16: ...can produce conditions which will deteriorate metal or damage the cata lyst Green or uncured wood does not work well as fuel and can cause increased creosote buildups and plugging of the catalytic co...

Страница 17: ...DUMP GASKET A 3 4 spun fiberglass gasket provides the seal around the fuel door and a flat spun fiberglass rope gasket 1 8 x 1 provides the seal around the glass A cerawool pad 4 1 4 x 4 1 4 x 1 2 pr...

Страница 18: ...age 19 for instructions on removing catalytic combus tor IMPORTANT MAKE SURE THE BYPASS DAMPER IS IN THE OPEN POSITION PRIOR TO CHIMNEY CLEANING In the event of a chimney fire Make sure the fuel door...

Страница 19: ...ed water for 30 minutes Then rinse by soak ing in hot distilled water After 15 minutes remove the combustor from the rinse water and gently shake out excess water It is unlikely that you will notice a...

Страница 20: ...t seal on the fuel door ash dump cover or glass is leaking air Repair or replace it if necessary 4 There is an obstruction in the chimney 5 The stove was not up to normal operating tempera ture before...

Страница 21: ...ecessary for achieving the required flow of combustion air to the fire chamber and for safely removing unwanted combustion byproducts from the appliance If the venting system s design does not promote...

Страница 22: ...mm Back of Stove to Center of Flue 5 1 2 140mm Approx burn time 8 10 hours Fuel capacity 70 lbs 32 kg approx Firebox size cubic feet 2 4 c f 732 cubic mm Maximum Burn Rate 56 800 BTU EPA BTU Range 6...

Страница 23: ...damper bypass BV100 Probe Combustor Temperature 11485 Housing Combustor Room Air Blower Parts LB 101495 Blower Assembly includes 2 blowers w propellers mounting bracket and terminal block 11565 Disc L...

Страница 24: ...99 Paint Kit Metallic Black 12 oz Spray 6309 Firebox Parts 11709 Cover Ash Dump w Gasket 4 1 4 x 4 1 4 x 1 2 26M73 Damper Kit Includes damper linkage and rod FB10 Firebrick 4 1 2 x 1 1 4 FB11 Firebric...

Страница 25: ...G 26M73 CATALYTIC DAMPER COMPONENTS PRIMARY AIR CONTROL DRAFT MODULE CATALOG 26M68 HANDLE ASSEMBLY P N LB 102214 DOOR ASSEMBLY Cat No 14M72 Gold and Cat No H0533 Black Includes Handle Assembly Not Sho...

Страница 26: ...he blower system can be easily transferred to the other side of the insert along with the power cord by installing this cord changeover kit This kit consists of a reversed right and left panels with c...

Страница 27: ...SAFETY LISTING LABEL Model BV4000C 2 PAGE 27 fire parts com...

Страница 28: ...EPA LABEL Model BV4000C 2 PAGE 28 fire parts com...

Страница 29: ...CORDS PAGE 29 Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description fir...

Страница 30: ...1110 West Taft Avenue Orange CA 92865 fire parts com...

Отзывы: