INSTALLATION
PAGE 11
14. Push the unit back until face shield insulation is
compressed against the fireplace front, forming a
tight seal.
Test for air leaks by holding a candle
around edge of face shield to see if smoke is
pulled into fireplace.
* Note: Preferred method of attaching connector to flue
outlet is to install two L-Brackets (1” angle bracket, 3/4”
wide) on opposite sides of the flue outlet: Use self-
tapping screws to secure in place. Cut a ½” (height) and
¾” (width) notch in the front of connector (pipe, liner or
adapter that will attach to flue outlet). Install connector
into flue outlet and secure to angle brackets using ma-
chine screws. Seal around connection with furnace ce-
ment.
POSITIVE FLUE CONNECTION FOR MASONRY
FIREPLACE
A Professional should inspect chimney prior to installa-
tion to determine if any repairs are necessary or if a
chimney reline is necessary.
The fireplace damper must be secured in the open posi-
tion. If this is not possible, it will be necessary to remove
the damper. Installation into a masonry fireplace re-
quires as a minimum of a flue extension past the
header. This can be accomplished by one of the follow-
ing methods:
Install 6" smoke pipe if the chimney is located di-
rectly above the insert flue
(Or) Install 6" flex pipe to achieve the same result.
Use an offset adapter (see page 25) to handle offsets.
This part is available through your dealer.
A preferable installation is the positive flue connection
(a positive seal between the flue extension and the
chimney). This can be achieved by using a filler plate. A
filler plate can be made by making a cardboard pattern
to fit the fireplace throat. Lay the pattern on 22 gage
steel, add 2 inches to each side, and cut. Snip corners
and bend front lip up and sides and back down. Cut an
opening for the flue. Attach filler plate with masonry
screws.
The starter pipe extends through the filler plate,
past the damper and into the chimney system.
Small air leaks should be sealed with high temp fi-
berglass or ceramic insulation.
FILLER
PLATE
f i r e - p a r t s . c o m