INSTALLATION
PAGE 8
FIREPLACE INSTALLATION
•
USA only - All masonry fireplace installations
require a minimum positive flue connection us-
ing a block-off plate or a positive seal past the
bottom of the chimney flue tile liner. In Canada,
a full reline is required.
•
Measure fireplace size to make certain the insert
will fit before considering the installation.
MINIMUM FIREBOX DIMENSIONS
Note: Measure fireplace size to make certain the in-
sert will fit before considering the installation.
Minimum size required for fireplace firebox (recessed
area into fireplace):
Height
21” / 533 mm
Width
22 1/2” / 572 mm
Depth
16” / 406 mm
MASONRY FIREPLACE:
USA APPROVED LINER –
6” DIA. FLEX OR
RIGID 24/26 MSG BLACK OR
BLUED STEEL PIPE OR 2100
°
HT LINER
CANADA APPROVED LINER –
S635 FLUE LINER
FACTORY BUILT (ZC)
FIREPLACE (USA ONLY) –
APPROVED LINER – 6” DI-
AMETER 2100
°
HT LINER
REMOVE FIRE-
PLACE DAMPER OR
SECURE OPEN
CHIMNEY
TERMINATION CAP
ENSURE CHIMNEY
IS SOUND
22 ½” / 572 mm
16” /
406 mm
21”
22 ½”