PLANNING YOUR INSTALLATION
PAGE 6
FACTORY BUILT FIREPLACES
(Not Approved In Canada)
In the USA, this appliance is approved for installation into
a listed factory built solid fuel burning fireplace (built to
UL 127 or ULC S610 standards). The fireplace firebox
must accept the insert without modification other than
removing bolted or screwed together pieces such as
smoke shelf/deflectors, ash lips, screen or door tracks
and damper assemblies, that must be reinstalled to re-
store the fireplace to its original operating condition if
the insert is removed and not replaced. The removal of
any part must not alter the integrity or outer shell of the
pre-engineered fireplace cabinet in any way.
Venting Requirements for factory built fireplace:
The fireplace damper must be secured in the open po-
sition. This appliance requires the use of a 6” (152 mm)
diameter flex or rigid, UL1777 listed 2100
°
HT liner or
equivalent. The liner must extend from the flue outlet of
the appliance to termination. Do not face seal over fire-
place chimney cooling air systems. Offsets can be han-
dled with an offset adapter (it aligns starter pipe with
fireplace flue). For more information on the offset
adapter, see pages 9 and 25.
WARNING: DO NOT SUBSTITUTE THE HEAT
RATED 2100
°
HT LINER WITH ANY OTHER TYPE
LINE OR A FIRE MAY RESULT CAUSING PROP-
ERTY DAMAGE, PERSONAL INJURY OR LOSS
OF LIFE.
Factory Built Fireplace Installation
MASONRY FIREPLACES
Note: Measure fireplace size to make certain the insert
will fit before considering the installation.
This appliance is approved for installation into a ma-
sonry fireplace built to UBC 37 or ULC S628 standards.
Do not remove brick or mortar form the masonry fire-
place to accommodate this appliance.
IMPORTANT: Any opening between the masonry of
the fireplace and the facing masonry must be per-
manently sealed.
USA Requirements / Masonry Fireplaces -
The fire-
place damper must be secured in the open position. In
the USA, a flue extension past the fireplace header is
required as a minimum. A preferred installation is a
positive flue connection (sealing the throat of the chim-
ney). This appliance requires the use of a 6” (152 mm)
diameter flex or rigid single wall pipe, minimum 24 / 25
MSG black or blued steel connector pipe (stainless
steel recommended).
Canada Requirements / Masonry Fireplaces
- – This
fireplace insert must be installed into an approved solid
fuel Masonry fireplace only (installation into a factory
built fireplace is not approved). The fireplace damper
must be secured in the open position. The fireplace in-
sert must be installed with a continuous chimney liner of
6” / 152 mm diameter extending from the fireplace in-
sert to the top of the chimney. The chimney liner must
conform to the Class 3 requirements of CAN / ULC –
S635, Standard for Lining Systems for Existing Masonry
or Factory-Built Chimneys and Vents, or CAN / ULC –
S640 Standard for Lining Systems for New Masonry
Chimneys.