PROCUCT FEATURES AND CONTROLS 

 

PAGE 12 

ASH DRAWER

 

The large ash drawer located below the fuel door is de-

signed to make cleaning easier by containing the ashes in 

a removable drawer. 

 

 

CAUTION:  DO NOT OPERATE THE STOVE WITH THE 

ASH DUMP COVER OFF, AS THIS WILL PRODUCE EX-

TREME TEMPERATURES WITHIN THE STOVE (OVER-

FIRING) AND COULD CAUSE DAMAGE TO THE AP-

PLIANCE OR OTHER PROPERTY

 

(SUCH DAMAGE IS 

NOT COVERED BY THE MANUFACTURERS WAR-

RANTY). REPLACE THE ASH DUMP GASKET IF IT BE-

COMES FRAYED OR DAMAGED. 

 

BLOWER SYSTEM 

The 250-CFM room air circulation blower system comes 

equipped with a variable speed control (rheostat). The 

blower system can be operated manually or set to operated 

automatically (so the blowers will turn on when the insert is 

hot and turn off when the insert is cool). See Care and Op-

eration Section – 

Blower System 

on page 15. 

 

 

PRIMARY AIR CONTROL 

The primary combustion air delivery is controlled by the 

primary air control draft module (The control handle is lo-

cated above the fuel door). The heat output can be con-

trolled by sliding the handle to a higher or lower heat output 

setting (see following illustrations). The fuel, the amount of 

heat and burn times desired, the type of installation are all 

variables that will affect the control setting. The same con-

trol settings in a variety of installations will produce different 

results. You will need to try different settings so you can 

learn how much heat to expect and how long the fire will 

burn

 

 

Lower    Higher 

 

 

 

CATALYTIC BYPASS DAMPER CONTROL

 

The bypass damper control handle is located on the front of 
the insert (see above illustration). By pushing in or pulling 
out the handle, the operator can route the exhaust either 
through the catalytic combustor (pushed in) or directly up 
the flue (pulled out). When starting a fire or refueling, the 
handle must be pulled out. Once the fire is established it 
must be pushed in. 

 
CATALYTIC COMBUSTOR

 

How it works:

 From 5 to 30 percent of the chemical en-

ergy contained in every log escapes up the chimney when 

wood is burned in a conventional stove. The catalytic com-

bustor is designed to make use of this energy, converting it 

into useful heat as it lessens chimney creosote build-up 

and air pollution. The catalytic combustor consists of a du-

rable temperature resistant ceramic composition, which is 

extruded into a cellular, or honeycomb, configuration. After 

extrusion, this ceramic monolith is fired and then covered 

with a noble-metal catalyst. When wood smoke contacts 

this catalyst, chemical changes occur that causes the 

smoke to ignite at temperatures around 600

°

 F. Normally, 

smoke will ignite and burn only at temperatures around 

1000

°

 F. 

 

f i r e - p a r t s . c o m

Содержание BV4000C-2

Страница 1: ...RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE EPA CERTIFIED CATALYTIC WOOD BURNING FIREPLACE INSERT THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER READ ENTIRE MANUAL THOROUGHLY BEFORE INS...

Страница 2: ...tor glows you are overfiring Overfiring this ap pliance could cause a house fire Overfiring is a condition where the appliance is operated at temperatures above its design capabilities see Overfiring...

Страница 3: ...TIONS ON THE PURCHASE OF YOUR NEW WOOD BURNING FIREPLACE INSERT MANUFACTURED BY LENNOX HEARTH PROD UCTS When you purchased your new insert you joined the ranks of thousands of concerned individuals wh...

Страница 4: ...e partment for requirements in your area IMPORTANT THIS APPLIANCE IS NOT APPROVED FOR INSTALLATION INTO A MANUFACTURED MO BILE HOME IN CANADA OR IN THE USA FLOOR PROTECTION This appliance requires a h...

Страница 5: ...FOR COMBUSTION In well insulated and weather tight homes it may be diffi cult to establish a good draft up your chimney The poor draft is caused by a shortage of air in the house To pro vide the neede...

Страница 6: ...IFE Factory Built Fireplace Installation MASONRY FIREPLACES Note Measure fireplace size to make certain the insert will fit before considering the installation This appliance is approved for installat...

Страница 7: ...ue size should be no more than 3 three times the cross sec tional area of the size of the fireplace insert flue collar In this case that would be no larger than a 10 inch 254 mm diameter stack area ap...

Страница 8: ...Note Measure fireplace size to make certain the in sert will fit before considering the installation Minimum size required for fireplace firebox recessed area into fireplace Height 21 533 mm Width 22...

Страница 9: ...mmable adhesive i e RTV High Temperature Silicone rated 570 F 4 Use a large piece of cardboard or other protective material and place it in front of the fireplace to protect floor or carpet during ins...

Страница 10: ...r attach the positive flue connection to the insert See Note SURROUND ASSEMBLY PURCHASED SEPARATELY NOTE Do not face seal over chimney cooling air system on superior brand or any brand fireplace which...

Страница 11: ...open posi tion If this is not possible it will be necessary to remove the damper Installation into a masonry fireplace re quires as a minimum of a flue extension past the header This can be accomplish...

Страница 12: ...ill affect the control setting The same con trol settings in a variety of installations will produce different results You will need to try different settings so you can learn how much heat to expect...

Страница 13: ...handle to the 6 00 position See illustration above GLASS The Glass is a super heat resistant ceramic that with stands continuous temperatures up to 1390 F This tem perature is well beyond the tempera...

Страница 14: ...ring the refueling we recommend that the stove be refired for about 10 minutes with the bypass open to ensure a good draw is established and that the catalyst reaches 600 F The refiring will ensure su...

Страница 15: ...urned off by rotating the rheostat dial counterclockwise until it clicks CAUTION BURNING THE INSERT AT A HIGH BURN RATE FOR EXTENDED PERIODS WITHOUT RUN NING THE BLOWERS CAN CAUSE EXCESSIVE TEMPERATUR...

Страница 16: ...can produce conditions which will deteriorate metal or damage the cata lyst Green or uncured wood does not work well as fuel and can cause increased creosote buildups and plugging of the catalytic co...

Страница 17: ...DUMP GASKET A 3 4 spun fiberglass gasket provides the seal around the fuel door and a flat spun fiberglass rope gasket 1 8 x 1 provides the seal around the glass A cerawool pad 4 1 4 x 4 1 4 x 1 2 pr...

Страница 18: ...age 19 for instructions on removing catalytic combus tor IMPORTANT MAKE SURE THE BYPASS DAMPER IS IN THE OPEN POSITION PRIOR TO CHIMNEY CLEANING In the event of a chimney fire Make sure the fuel door...

Страница 19: ...ed water for 30 minutes Then rinse by soak ing in hot distilled water After 15 minutes remove the combustor from the rinse water and gently shake out excess water It is unlikely that you will notice a...

Страница 20: ...t seal on the fuel door ash dump cover or glass is leaking air Repair or replace it if necessary 4 There is an obstruction in the chimney 5 The stove was not up to normal operating tempera ture before...

Страница 21: ...ecessary for achieving the required flow of combustion air to the fire chamber and for safely removing unwanted combustion byproducts from the appliance If the venting system s design does not promote...

Страница 22: ...mm Back of Stove to Center of Flue 5 1 2 140mm Approx burn time 8 10 hours Fuel capacity 70 lbs 32 kg approx Firebox size cubic feet 2 4 c f 732 cubic mm Maximum Burn Rate 56 800 BTU EPA BTU Range 6...

Страница 23: ...damper bypass BV100 Probe Combustor Temperature 11485 Housing Combustor Room Air Blower Parts LB 101495 Blower Assembly includes 2 blowers w propellers mounting bracket and terminal block 11565 Disc L...

Страница 24: ...99 Paint Kit Metallic Black 12 oz Spray 6309 Firebox Parts 11709 Cover Ash Dump w Gasket 4 1 4 x 4 1 4 x 1 2 26M73 Damper Kit Includes damper linkage and rod FB10 Firebrick 4 1 2 x 1 1 4 FB11 Firebric...

Страница 25: ...G 26M73 CATALYTIC DAMPER COMPONENTS PRIMARY AIR CONTROL DRAFT MODULE CATALOG 26M68 HANDLE ASSEMBLY P N LB 102214 DOOR ASSEMBLY Cat No 14M72 Gold and Cat No H0533 Black Includes Handle Assembly Not Sho...

Страница 26: ...he blower system can be easily transferred to the other side of the insert along with the power cord by installing this cord changeover kit This kit consists of a reversed right and left panels with c...

Страница 27: ...SAFETY LISTING LABEL Model BV4000C 2 PAGE 27 fire parts com...

Страница 28: ...EPA LABEL Model BV4000C 2 PAGE 28 fire parts com...

Страница 29: ...CORDS PAGE 29 Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description fir...

Страница 30: ...1110 West Taft Avenue Orange CA 92865 fire parts com...

Отзывы: