6
PROBLEM
CAUSE
ACTION REQUIRED
The paint runs on the item
being sprayed
Paint too diluted
Add undiluted material
Paint volume too high
Reduce the paint flow by turning Fluid Adjusting Screw (12) clockwise
Moving too slowly
Increase speed of application
Spray gun trigger held too long
Release trigger earlier
Spray gun too close
Increase the distance between gun and work-piece
Paint is thin or irregular
Paint too diluted
Add undiluted material
Paint volume too low
Increase the paint flow by turning Fluid Adjusting Screw (12) anticlockwise
Moving too fast
Reduce speed of application
Spray gun clogged
Clean the spray gun
Spray gun too far away
Reduce the distance between gun and work-piece
No paint being produced
Paint too thick
Add thinners
Spray gun clogged
Clean the spray gun
Pick-up tube clogged
Clean Pick-Up Tube (24)
Air Hose split
Replace Air Hose (28)
Grainy paint
Filter the paint
Container almost empty
Refill Paint Container (17)
Spray gun at an angle
Ensure Pick-Up Tube (24) is angled towards paint
Air intake blocked
Check no paper or loose debris can block the air intake underneath the unit.
Clean or replace Filter (27) if necessary.
GUARANTEE
This product is guaranteed for a period of 24 months against faulty manufacture or materials. It is not guaranteed for industrial or hire purposes.
This guarantee does not affect your statutory rights. For further information or any user advice, please phone our helpline between 08.30 to 17.00
and Fridays 08.30 to 15.45 (excluding Bank Holidays), or visit our website www.earlex.com.
Design Registrations:
GB 2106529
DE 402 04 314.6
FR 02 3314
US D488,169S
Spray Gun Design Registration:
GB 3006933
Copyright & Design Right Reserved © 2012
PLEASE NOTE:
We have done all we can to ensure that used correctly and according to these instructions, this SprayStation will give long and
trouble-free life. We accept no responsibility for damage caused by the use of incorrect or unsuitable substances, paints or fluids which have not
been thinned correctly or are unsuitable for the surfaces to which they are applied, health hazards arising from lack of ventilation when working in
confined spaces or failure of the equipment due to inadequate cleaning of the components after use. If in doubt, always test a small inconspicuous
area first. Always read the paint manufacturer’s instructions first. Neither our guarantee nor the above statement affects your statutory rights.
EC Declaration of Conformity
We declare that the unit HV5500 conforms to LVD 2006/95/EC, EN60335-1, EMF EN62233;
EMC 2004/108/EC, EN55014-1, EN55014-2, EN61000-3-2, EN61000-3-3.
Tim Hopper Technical Director
Earlex Sarl.
Tel
: +33 (0)4 76 67 18 46
Website
: www.earlex.com
Earlex Ltd.
Tel
: +44 (0)1483 454666
Website
: www.earlex.com
TROUBLESHOOTING
MAINS CONNECTION
This unit is a Class II appliance which means it is double-insulated for your protection, no earthing wire is necessary. If the supply cord is
damaged, it must be replaced by Earlex Ltd or our appointed agents to avoid a hazard.
If you are using an extension cord it must be rated at a minimum of 6 Amps and fully unwound. Do not operate with a lead rated at less
than 6 Amps as this will cause premature failure of the motor which is not covered by the guarantee.
If the plug is cut off from the mains cord, the plug must be disposed of safely. NEVER under any circumstances insert a plug which is cut
off from the mains cord into a socket-outlet.
The turbine unit only requires minimal maintenance.
●
Ensure its Filter (27) element is kept clean at all times.
This is the filter underneath the main body of the turbine. Disconnect the unit from the power supply, turn on side and remove filter. This
can be washed out if necessary and replaced when dry. From time to time this filter will need replacing (Part No. L0058).
●
The turbine bearings are sealed and lubricated for life. There is no maintenance or adjustment required.
●
Clean the turbine and hose unit with a damp cloth after use.
●
The hose is stowed by coiling it between the motor housing and hose cover.
●
The power cord is stowed by wrapping around the base of the unit and locating the plug in the space at the back of the unit.
TURBINE UNIT
Содержание Spray Station HV5500
Страница 1: ......
Страница 33: ...33 Earlex Ltd 8 Earlex Earlex 85 31 22 17 2 23 28 3 2 2 2 1 2 RU...
Страница 37: ...37...
Страница 38: ...38...
Страница 39: ...39...