ET DC BLUE ADVANCED INSTALLER 2012.025.12.05.2014
4
•
Installation:
o
Remove all cables, latches/locks or catches not necessary for automation.
o
Ensure the working area is clear of obstructions and obstacles.
o
Install the door sticker depicting the safety reverse test and keeping door area clear. This sticker should
be fixed to the inside surface of the door or near any permanent door control switches such as a wall
console if installed.
o
The emergency release cord must be installed where it is no higher than 1.8m from the floor level.
o
Any additional fixed door control switches such as wall consoles, if installed, must be at a height of at
least 1,5m, within clear sight of the door and away from any moving components of the system.
o
Do not substitute any component of DC Blue Advanced with any other manufacturer’s part. ET
Systems accepts no responsibility for the safety and correct operation of the automation system if any
of these points are ignored.
•
After Installation: It is the responsibility of the installer to ensure the user:
o
Is proficient in the use of the manual emergency release mechanism.
o
Is issued with the documentation accompanying this product.
o
Understands that the door may not be operated out of clear sight.
o
Ensures that children are kept clear of the door area and that children do not play with the remote
transmitters.
o
Is instructed not to attempt to repair or adjust the automation system and to be aware of the danger
of continuing to use the automation system in an unsafe condition before a service provider attends to
it.
o
Is proficient in testing the unit’s safety obstruction sensing system by means of placing a 40mm high
object (wooden block) below the door in the closed position. On contact with the object the unit must
reverse the door away and back to the open position.
* Based on the assumption that the door is balanced correctly and moving freely.
TECHNICAL SPECIFICATIONS
Primary power supply
220 – 240Vac @ 50hz
Power consumption
120W peak @ (220 -240vac)
Motor voltage
24V dc
Maximum operations per day
50 full cycles per 24hrs @ a rate of Max. 2 per hour
Traveller speed*
8m/min
Operating temperature range
-10 to 50° C (14F to 122F)
Anti-crushing safety sensing
Yes - Electronic digital profiling
Auxiliary supply output
24Vdc @ 250mA peak or 150mA continuous
Rated battery charging voltage
27.5Vdc
Built in receiver format
ET BLU MIX © enhanced rolling code.
Receiver frequency
433.92Mhz
Memory
EEPROM
Applicable door types
One piece trackless tip-up or multiple panel sectional
overhead doors
Drawbar options(Ex-stock)
2.2m or 3.2m or 3.7m
Applicable door sizes
<13m²