E.T. Systems DC BLUE ADVANCED Скачать руководство пользователя страница 3

ET DC BLUE ADVANCED INSTALLER 2012.025.12.05.2014 

 

www.et.co.za 

 

 

IMPORTANT WARNINGS TO THE INSTALLER AND GENERAL SAFETY OBLIGATIONS 

 

 

Caution!  It is important for personal safety to follow all the instructions carefully. Incorrect installation or misuse 

may  cause serious personal harm. 

 

 

Keep the instructions in a safe place for future reference.  

 

 

This product was designed and  manufactured strictly for the use indicated in this documentation. Any  other use 

not expressly indicated in this documentation, may  damage  the product and/or  be a  source of danger.  

 

 

We accept no responsibility due to improper use or incorrect installation of this product. 

 

 

We will not accept responsibility if the principles of good workmanship are disregarded by  the installer.  The 

construction of the door  must be  sound  and  automatable.  It is the  responsibility of the installer to ensure that all 

mountings to the door are sufficient to withstand the necessary forces in cases of overload.  

 

 

It is highly  recommended that a  set of safety infra-red beams be  used in conjunction with this product.  

 

 

Over and  above the recommendation to use safety infra-red beams  with this product it is mandatory  to install 

and  use a  safety beam  set when using the automatic closing feature.  

 

 

We accept no responsibility regarding safety and  correct operation of the automation if other manufacturer’s 

equipment is added  to this product.  

 

 

Do not make any  modifications or alterations to this product.  

 

 

Anything other than expressly provided for in these instructions is not permitted. 

 

 

Prior to  installation:    

o

 

The  door must be balanced  correctly to the tensioning system. When operated by  hand  the door 

should be free of hindrance and  easily moved. When left at any  position in its travel, the door should 

neither rise nor fall. If the door does rise or fall, re-balance the tensioning system. (Tensioning should only 

be carried out by a qualified and experienced person)   

o

 

The  door material must be  sound and  whole. Ensure  the areas where the operator attaches have been 

re-enforced. The door hardware must be in good serviceable condition.   

o

 

Ensure the wall above the door is sound  and  strong enough  to allow proper fixing of the operator.   If 

necessary use through bolts and/or cross brace plate to spread the load. (Typically on cinder brick or 

hollow walls)  

o

 

The DC Blue Advanced is designed for weatherproof applications only. Install in completely walled and 

roofed garages only.   

o

 

Ensure the area of installation is not subject to explosive hazards.   There should be no volatile gasses or 

fumes as these can  present a serious safety hazard. 

o

 

The  DC  Blue Advanced is designed to be  used in low traffic applications only. Do not install on doors 

used for multi parking garages like office parks or apartment blocks with a single entrance.  

o

 

The DC Blue Advanced is supplied with a sealed 15A safety plug on lead for use in an electrical code 

of practice approved plug point. Do not extend, modify or replace the plug lead unless duly qualified 

as an  electrician. Before installing the unit, ensure the mains  supply is switched off.   

 

o

 

It is the responsibility of the installer to ascertain that the designated persons (including children) 

intended to use the system, do not suffer reduced physical sensory or mental capabilities, or lack of 

experience and knowledge, unless they have been given supervision or instruction concerning the use 

of the system by  a person responsible for their safety.  

o

 

The  drive may not be  installed on a  door incorporating a wicket door, unless the drive is disabled by the 

release of the wicket door.  (Wicket door :- A pedestrian door within the main door) 

Cont.….. 

 

Содержание DC BLUE ADVANCED

Страница 1: ...ET DC BLUE ADVANCED INSTALLER 2012 025 12 05 2014 1 www et co za Domestic garage door operator Installer Instructions ...

Страница 2: ...ring and setup 12 Wiring of optional extra devices to the system 13 Control panel dashboard and programming menu summary How to navigate the menu 14 Programming Open and closed limit setup and door load profiling 15 Programming Setting the obstruction force sensing safety level 16 Programming Activating safety beam mode 17 Programming Activating and selecting the auto close time 18 Programming Sel...

Страница 3: ... positioninits travel the door should neither rise nor fall If the door does rise or fall re balance the tensioning system Tensioning should only be carriedout by a qualifiedand experiencedperson o The door material must be sound and whole Ensure the areas where the operator attaches have been re enforced The door hardware must be in good serviceable condition o Ensure the wall above the door is s...

Страница 4: ...e door may not be operatedout of clear sight o Ensures that childrenare kept clear of the door area and that childrendo not play withthe remote transmitters o Is instructednot to attempt to repair or adjust the automationsystemand to be aware of the danger of continuing to use the automationsystemin an unsafe conditionbefore a service providerattends to it o Is proficient intesting the unit s safe...

Страница 5: ... screws M6 x 20mm 4 27 Motor head 1 9 Emergency release cord1 1m with warning tag 1 28 Control panel dashboard 1 10 Emergency release cordplastic knob handle 1 29 Courtesy light diffuser lens 1 11 Pivot pins 8mm x 25mm 2 30 Drawbar 1 12 Hanging strap drawbar attachment bracket 1 31 Drawbar spring dampener and shock absorber 1 13 Drawbar brackets 3 32 Batteryconnectionbeneathdust cover sticker 1 14...

Страница 6: ...ledge traveller Ensure the 4 machine screws are securely fastened Do this prior to installing the drawbar CAUTION TO DISENGAGE AND MOVE DOOR MANUALLY Warning Door may plummet closed when released W hile pulling t he emergency release cord dow nw ard move t he door open or closed by hand TO RE ENGAGEAND LOCK DOOR BACK ONTO DRIVE Let t he cord go and move door open or closed unt il the sledge t rave...

Страница 7: ...cket in the case of a standard single track or double track overhead sectional garage door system NB The wall mount bracket is one of the components that take the majority of the load in a garage door automation system Extra care needs to be taken to ensure the bracket is securely fastened and that whatever the bracket is fastened to can withstand force equal to the force of the door when the spri...

Страница 8: ... a garage door automation system Extra care needs to be taken to ensure that the bracket is securely fastened Whatever the bracket is fastened to must also withstand a force equal to the force of the door when the spring balancing of the door is removed For example if a balancing spring snaps INSTALLING THE LINK ARM See page 5 for component identification Close the door fully Install the curved li...

Страница 9: ...the wall mount bracket at this height where it is positioned above the centre of the door as shown in the diagram below NB The wall mount bracket is one of the components that will take the majority of the load in a garage door automation system Extra care needs to be taken to ensure that the bracket is securely fastened Whatever the bracket is fastened to must also withstand a force equal to the ...

Страница 10: ...e cotter pins Raise the drawbar up and out of the way of the door Install the link arm into both the sledge traveller and door mount bracket using the 25mm pivot pins and remaining two cotter pins Prepare and install the hanging straps so that when the door is in the full open position the link arm lays 180 to the door Do not use the curved link arm extension in this type of installation The diagr...

Страница 11: ...4 of the M6 Nylock nuts fasten the battery atop the drawbar as shown below Remove the sticker covering the battery plug socket on the motor head and insert the battery lead plug The battery plug is moulded in such a way as to only be inserted in one direction Ensure the plug is in firmly SUPPLYING HOUSEHOLD POWER TO THE MOTOR HEAD The DC BLUE ADVANCED comes supplied with an IEC and SANS compliant ...

Страница 12: ...ET DC BLUE ADVANCED INSTALLER 2012 025 12 05 2014 12 www et co za OPTIONAL EXTRA DEVICES WIRING CONNECTIONS ...

Страница 13: ... the SET button until the buzzer beeps twice Once in the Programming menu use the up and down buttons to scroll between options For further instruction on changing settings refer to the instruction tables on the page indicated for each option EXIT BUTTON To exit a setup option without changing the current setting for that option press and release the EXIT button The menu will exit back one level N...

Страница 14: ...firm the door direction while fine tuning or When satisfied the door is in the correct open position press the SET button to advance to the close limit setup The buzzer beeps once and the C symbol displays to indicate the closed limit position must be set Press and hold the DOWN button to lower the door to the required closed position The u symbol displays as the door closes Fine tune using the UP...

Страница 15: ...EL Default level 3 From Standby Mode Action Response To enter the Program menu Press and hold SET button until buzzer beeps twice Display begins flashing P and buzzer beeps twice to confirm the main program menu is active Scroll up with the UP button until F flashes Display flashes F to confirm safety force setup mode is selected Press and release SET button to enter safety force setup Buzzer beep...

Страница 16: ...ins flashing P and buzzer beeps twice to confirm the main program menu is active Select safety beams setup by scrolling up with the UP button until b flashes Display flashes b to confirm safety beam setup mode is selected Press and release SET button to enter safety beam setup Buzzer beeps once and current beam status is displayed 0 Off and 1 On Press and release the UP button for On or DOWN butto...

Страница 17: ...shing P and buzzer beeps twice to confirm the main program menu is active Select auto close setup by scrolling up with the UP button until A flashes Display flashes A to confirm auto close setup mode is selected Press and release SET button to enter auto close setup Buzzer beeps once and current auto close status is displayed Press and release the UP or DOWN buttons to scroll to the desired settin...

Страница 18: ...motor starts opening and 5 seconds later the lock relay module switches off again Total 5sec pulse length From Standby Mode Action Response To enter the Program menu Press and hold SET button until buzzer beeps twice Display begins flashing P and buzzer beeps twice to confirm the main program menu is active Select lock setup by scrolling up with the UP button until flashes Display flashes to confi...

Страница 19: ...r receiver programming Buzzer beeps once and b for BT is displayed Press and release the UP or DOWN buttons to scroll to the channel the remote button must be learnt into b BT button trigger channel L LT Courtesy light trigger channel or Press and hold desired remote button LED on remote transmitter illuminates While still holding the desired remote button press and release the SET button 1 on dis...

Страница 20: ...p by scrolling up with the UP button until r flashes Display flashes r to confirm receiver setup mode is selected Press and release SET button to enter receiver setup Buzzer beeps once and b is displayed Press and release the UP or DOWN buttons to scroll to the C option C is displayed Press and hold desired remote button to be erased LED on remote transmitter illuminates While still holding the de...

Страница 21: ...ll to the E option E is displayed Press and hold SET button and do not release While still holding the SET button Press and release UP button to start master erase Release both buttons once beeps begin Display flashes E and buzzer beeps intermittently to warn that master erase is about to begin NB Pressing and holding EXIT at this point will abort the master erase Master erase routine is running W...

Страница 22: ...and display shows b Buzzer beeps once and display shows b Press and hold required remote button LED on remote transmitter remains lit Press and release the SET button 1 on display and 1 beep user code successfully registered 2 on display and 2 beeps user code already in the receiver memory 3 on display and 3 beeps Unsuccessful because no code was seen within 4 sec of the SET button being pressed M...

Страница 23: ... hardwired trigger Door begins opening and courtesy light switches on Wait for door to reach the full open position Door stops and waits in the open position Courtesy light remains on for a further 3 minutes Press and release either the remote button trigger or the hardwired trigger Door begins closing and if the courtesy light had previously timed out and switched off it will switch on again for ...

Страница 24: ...and release either the remote button trigger or the hardwired trigger before the door reaches the full open position Door stops and waits for next instruction Courtesy light remains on for a further 3 minutes Press and release either the remote button trigger or the hardwired trigger Door begins closing and if the courtesy light had previously timed out and switched off it will switch on again for...

Страница 25: ...s on Stop door while opening or simply wait until it reaches the open position Door stops and waits at the required open position Courtesy light remains on for a further 3 minutes Press and hold the remote button trigger 10 seconds until buzzer beeps Buzzer beeps rapidly to indicate party mode is active TO CONFIRM Any attempt to operate the door normally Buzzer repeats rapid beeps to indicate the ...

Страница 26: ...s on Whilst buzzer is still sounding Press and release the remote trigger button to activate Holiday lock out Buzzer beeps light flashes rapidly and display shows H to indicate Holiday lock out is active TO CONFIRM Any attempt to operate the door normally Buzzer beeps light flashes rapidly and display shows H to indicate Holiday lock out is active TO DE ACTIVATE Press and hold remote courtesy ligh...

Страница 27: ...osed position Courtesy light off Lock relay module off Press and release either the remote button trigger or the hardwired trigger 0 5 seconds before the door begins opening the lock relay module and courtesy light switches on Door begins opening lock relay module and courtesy light remains on 0 5 seconds after door begins opening the lock relay module switches off again Door continues opening and...

Страница 28: ...closed position Courtesy light and lock relay module off Press and release either the remote button trigger or the hardwired trigger 0 5 seconds before the door begins opening the lock relay module and courtesy light switches on Door begins opening lock relay module and courtesy light remains on 5 seconds after door begins opening the lock relay module switches off again Door continues opening and...

Страница 29: ...and buzzer flashes and sounds three times before door begins closing automatically ADVANCED FEATURES Safety beam input NB This input only affects the closing cycle Action Response Door closing Light on Interrupt the safety beams Display shows b door stops and begins opening once again Light remains on Safety beam still interrupted Door reaches full open position Display continues to show b as long...

Страница 30: ...ter any BT transaction when the household mains power is off Action Response Every operation of the door from any position Light will come on for 3 minutes and door operates If the light is off and the L courtesy light button on the remote is pressed and released Light will come on for 60 minutes If the light is on and the L courtesy light button on the remote is pressed and released The courtesy ...

Страница 31: ...On battery power only Re connect household mains supply To test Check that light switches on when operating door Page 30 Door stops Motor fuse blown or Encoder faulty or disconnected Replace motor fuse or Reconnect or replace encoder Press and release EXIT when done WARNINGS WHEN ATTEMPTING TO PROGRAM THE OPEN AND CLOSED LIMITS AND DOOR PROFILING Display Buzzer and door Reason Resolve by Door stop...

Страница 32: ... accompanied by the original invoice All claims made by the end user must be directedto their respective service provider installer The following conditions will disqualifythis product fromthe warranty as laid out above These conditions are non negotiable Any unauthorized non manufacturer modifications to the product or components thereof The use of the ET DC BLUE ADVANCED operator inheavy traffic...

Отзывы: