APPENDIX C: EMULATOR II ERROR MESSAGES
If you ask the Emulator II to do something it doesn’t want to do, it will give an error message in
the display. If you encounter one of the following, it will be for the reason given.
All Tracks Empty:
This occurs if you refer to a Sequencer track but none has been recorded.
Assigned to Trk#:
Occurs with the Sequencer if you try to store a control destination that has
already been assigned to a track (track # indicated in message).
Awaiting SMPTE:
SMPTE time code has not yet been received by the Emulator II, or cannot be
read.
Exists Again:
With Get Voice (PRESET DEFINITION II), you cannot over-write an existing
Voice.
Illegal Asgnment:
When assigning Voices to a Preset, this message indicates the high key is
below the low key, or the low key is above the high key.
Insert Library Disk and Press Enter:
You have asked for a Library disk function but have not
inserted a Library disk or have some other drive problem.
Insert Performance Disk and Press Enter:
You have asked for a Performance disk function
but have not inserted a Performance disk or have some other drive problem.
Key Must Have 2 Voices Assigned:
Occurs with Velocity Crossfade, Velocity Switch, and
Positional Crossfade if the key does not have two Voices assigned.
Need More Room:
You have run out of sampling space.
No Current Voice:
Occurs when entering the Voice Definition, Filter~ or VCA/LFO modules;
assign a Current Voice to the keyboard.
No Voices Available:
All 99 Voices have been used up or you are looking for Voices where
none exist.
No Voice in Preset:
If no voice has been assigned to the Preset, this message occurs when
you enter module requiring a Current Voice.
Not Enough Voices:
Occurs if you try to replicate a Preset, but there are more Voices in the
Preset than there are available in the Bank.
Not Found:
You have specified a non-existent Preset.
Presets Different:
When punching with the Sequencer, the Current Preset must be the same
as the Preset assigned to the Current record track.
Preset Not Saved:
Usually occurs when trying to save a Preset with insufficient Bank memory.
Содержание EII+
Страница 11: ...INTRODUCTION 1985 1986 1987 E mu Systems Inc Page 11 INTRODUCTION ...
Страница 20: ...INTRODUCTION 1985 1986 1987 E mu Systems Inc Page 20 ...
Страница 26: ...THE GUIDED TOURS 1985 1986 1987 E mu Systems Inc Page 26 THE GUIDED TOURS ...
Страница 84: ...VOICE DEFINITION MODULE 1985 1986 1987 E mu Systems Inc Page 84 Fig VDEF 8 Fig VDEF 9 ...
Страница 118: ...PRESET DEFINITION MODULE 1985 1986 1987 E mu Systems Inc Page 118 ...
Страница 168: ...ENTER MODULE 1985 1986 1987 E mu Systems Inc Page 168 ENTER MODULE ...
Страница 170: ...SEQUENCER MODULE 1985 1986 1987 E mu Systems Inc Page 170 SEQUENCER MODULE BACKGROUND EXT CLOCK SETUP EDIT ...
Страница 214: ...SMPTE SUPPLEMENT 1985 1986 1987 E mu Systems Inc Page 214 SMPTE SUPPLEMENT OVERVIEW PROTOCOL ...