SEQUENCER MODULE
© 1985, 1986, 1987 E-mu Systems, Inc. Page 175
3. Move Slider A upwards to the next step in the Ext Clock setup routine, which
determines the click rate when reading a click track. Slider D chooses the
options. The display initially gives the default value:
Click Rate: 24pqn
Use Slider D
With this setting (24 pulses-per-quarter note), a quarter note occurs for every 24
clock pulses received at the SMPTE IN jack. The E-mu Drumulator, most Roland
equipment, PAIA Master Synchronizer, and most drum machines use this
standard. Move Slider D upwards from the bottom of its travel and the display
says:
Click Rate: 48pqn
Use Slider D
With this setting, a quarter note occurs for every 48 clock pulses received at the
SMPTE IN jack. The LinnDrum and some Korg equipment use this standard.
Move Slider D upwards and the display says:
Click Rate: 96pqn
Use Slider D
This is the standard used by Oberheim Electronics. When the display shows the
desired click rate, proceed to the next step in the setup.
4. Move Slider A upwards to the next step in the Ext Clock setup routine; the
display says:
Write Click Trk?
Press Yes
To generate a 24 pulses-per-quarter note click track signal at the MET OUT jack
suitable for recording on tape, press YES. Note that the tempo should be set as
desired before writing (see SEQUENCER SETUP 2, “Tempo”). After pressing
YES, the display says:
Writing…Press
Enter to Stop
Use this signal to set record levels before rolling tape. Set about a -3 VU record
level. After setting levels, press ENTER to stop writing. Roll the tape in record
mode, leave a few seconds of blank tape, then press YES to start recording the
click track on tape.
Always record more click track than you think you’ll need. You can erase it later if
you don’t use it, and if you ever need it you’ll be g-lad it’s there.
Содержание EII+
Страница 11: ...INTRODUCTION 1985 1986 1987 E mu Systems Inc Page 11 INTRODUCTION ...
Страница 20: ...INTRODUCTION 1985 1986 1987 E mu Systems Inc Page 20 ...
Страница 26: ...THE GUIDED TOURS 1985 1986 1987 E mu Systems Inc Page 26 THE GUIDED TOURS ...
Страница 84: ...VOICE DEFINITION MODULE 1985 1986 1987 E mu Systems Inc Page 84 Fig VDEF 8 Fig VDEF 9 ...
Страница 118: ...PRESET DEFINITION MODULE 1985 1986 1987 E mu Systems Inc Page 118 ...
Страница 168: ...ENTER MODULE 1985 1986 1987 E mu Systems Inc Page 168 ENTER MODULE ...
Страница 170: ...SEQUENCER MODULE 1985 1986 1987 E mu Systems Inc Page 170 SEQUENCER MODULE BACKGROUND EXT CLOCK SETUP EDIT ...
Страница 214: ...SMPTE SUPPLEMENT 1985 1986 1987 E mu Systems Inc Page 214 SMPTE SUPPLEMENT OVERVIEW PROTOCOL ...