39
Jbus
MODbus
Description
Display
Attribute
Address
Address
Code
223
222
Tare calibration
(“tARE”)
W
Range:
0 = Disable calibration
1 = Enable calibration
224
223
Last calibration status
R
Range:
0 = Idle
1 = calibration in progress
3 = calibration done without error
4 = calibration done with error
Notes: After reading, the word is set
to 0 if the value read is 3 or 4.
225
224
Peak reset W
Range:
0 = No operation
1 = Peak reset
226
225
Manual reset of alarm 1 condition W
Range:
0 = No operation
1 = Reset alarm 1
227
226
Manual reset of alarm 2 condition W
Range:
0 = No operation
1 = Reset alarm 2
228
227
Load default control parameters value W
Range:
0 = No operation
1 = Load default
Notes: Refer to device manual for listing
of default value.
45
Содержание 1392 Series
Страница 29: ...29 10 0 CE DECLATION OF CONFORMATY...