25
8.3 Default Data Loading Procedure
In each one of the Indicator’s three modes, configuration, calibration and operation, you can load
default data to reset all of the parameters for that particular mode.
To load the default data:
Press + , and once the display shows
dF OFF,
press . When the display shows
dF On,
press
FUNC
. Default data will now be loaded. During data loading time the display will show
L.dAtA.
The default data for the three modes are shown on the following pages.
Note:
Certain default data will vary depending on the region the unit was sold.
8.3.1 Default Data for Configuration Parameters
Description
Default Setting
Input Type J
Units C
Decimal point position - - - - . -
Full scale units
1200.0
Low scale units 200.0
Display filter time constant
.4 mS
Input interrupt
High
External contact function
Alarm manual reset
Contact status
Closure
Alarm 1 operating mode
High with automatic reset
Alarm 1 action
Reverse
Alarm 1 masking option
Disable
Alarm 1 filter
Off
Alarm 1 hysteresis
1.0%
Alarm 2 operating mode
High with automatic reset
Alarm 2 action
Reverse
Alarm 2 masking option
Disable
Alarm 2 filter
Off
Alarm 2 hysteresis
1.0%
Serial communication type
Off (w/o RS-485)
MODbus
(w/RS-485)
Serial communication address
1
Serial communication baud rate
19200
Serial communication byte format 8
no parity
Analog retransmission type
4 - 20 mA (if fitted)
Analog retransmission low scale value 0.00
Analog retransmission high scale value 1500.0
Analog retransmission filter
.4