38
Jbus
MODbus
Description
Display
Attribute
Address
Address
Code
130
129
Status alarm 2 R
Range:
0 = No alarm
1 = Alarm
*131
130
Alarm 1 threshold RWDM
*132
131
Alarm 2 threshold RWDM
134
133
Input variable without filter RDM
Notes: When an error is detected on
measure, the”Data field” contains one
of these error codes:
30002 (7532h) = Open sensor ckt
30004 (7534h) = Under-range
30005 (7535h) = Over-range
30050 (7562h) = Error on internal auto-zero
30053 (7565h) = Calibration span too small
(<= 7% of input span)
*218
217
Lock/unlock device status RW
Range:
0 = Unlock device
1 = Lock device
*219
218
Local/remote device status RW
Range:
0 = Device in local
1 = Device in remote
Notes: See note 6 at page 40.
220
219
Unsolicited request flag R
Range:
0 = No Parameters change has occurred
1 = change has occurred on parameters
marked with *Notes: The word is set at
the start-up. Changes produced by serial
link will not be flagged.
The word resets after reading.
44