16
5.2.1.2 Relative To Other Sensors
For optimum performance sensors should be mounted so their position is offset by a
minimum of ½ inch from the sensors immediately adjacent to them. This ensures each
sensor’s cameras have a clear field of view of only it’s own lasers.
For systems with both Top and Bottom mounted sensors, each Top-Bottom pair of
sensors should have the same offset distance.
The diagram below illustrates the relative positioning of sensors in a system.
Figure 5.3
– B800 sensor offset (staggering) configuration
In Top-Bottom scanner systems, each Top-Bottom pair of sensors should be positioned
so that the lasers are pointed directly into the aperture windows of the opposing sensor.
The mounting holes of the B800 heads have been slotted to allow precise side to side
positioning to align opposing lasers.