![Dynasound DS3002 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/dynasound/ds3002/ds3002_manual_2548806009.webp)
Windows network setup
Dynasound, Inc. 6439 Atlantic Blvd. Norcross, GA. 30071 800.989.6275
Connecting your computer to the soundmasking network
Communications between the Windows based PC and the DS3002/3008 and networked DS8000s are done via a 100
base-T switched network connection. You must set your PC Network Interface Card to a fixed IP as shown below. The
DS3002/DS3008 default factory IP address 192.168.100.5. Default IP addresses for DS8000s are 192.168.100.6 through
192.168.100.200. You should set your computers network IP to a fixed IP, out of the range of other network devices, such
as 192.168.100.240.
Insert the USB drive provided with the DS3002/DS3008/DS8000. Open the drive and run the setup program provided.
You
can also download the latest version of Privacy Manager from www.soundmasking.com/support.html.
Privacy Manager
6
Configuring Privacy Manager for your soundmasking network
The default IP search range is set to the default IP address of
a DS3002 or DS3008 (192.168.100.5). If additional devices are
being used the range of IP addresses in your system must be
entered into the Network Setup screen.
If there are unused IP addresses between the starting and
ending numbers, the unused numbers should be entered into
the exclusion field so that, during operation, Privacy Manager
software is not delayed attempting to locate non-existing
devices. For exception IP addresses enter only the last segment
of the IP address. Complex exceptions may be specified similar
to page numbers in a word processor. For example you could
exclude devices 5,8,10-15,20 which would exclude IPs ending
in 5,8,10,11,12,13,14,15 and 20.
If Privacy Manager is already installed and configured you can skip this section and proceed to the next page. If not proceed