![Dynasound DS3002 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/dynasound/ds3002/ds3002_manual_2548806016.webp)
13
Dynasound, Inc. 6439 Atlantic Blvd. Norcross, GA. 30071 800.989.6275
Device properties, such as Zone ID, can be edited
while connected to a specific DS3002/3008/8000. While
connected to a device, simply double-click the field you
wish to edit and enter the changes. The following device
properties can be edited:
• location ID
• control zone
• transmit bundle ID
• receive bundle ID
• device IP address
• device notes
• soundmasking schedule
• soft start schedule
Changing IP addresses can make the DS3002, DS3008 or DS8000 become unreachable. All IP addresses must fall
within a range that is compatible with the setting on your PC’s network connection.
Device properties
!
6)
notes:
This is a text field that is used to store user comments or notes for a specific device.
5)
IP address:
A static IP address is normally defined for each network device before leaving Dynasound. Once a system
is in place and configured there is normally no need to change an IP address.
1)
location ID
:
The location is a text field that represents a physical location in the building and on the as-built drawings.
It is used to identify the location of DS8000s. The normal naming convention is the floor number and a sequential number
representing each DS8000. For example the 3 ea. DS8000s on the third floor would be 3.1 , 3.2 and 3.3.
2)
control zone:
Control Zone is a text field that can be various formats, however zone names are case-sensitive and care
must be taken to properly group DS8000s into cutomized Control Zones.
3)
transmit bundle ID:
The default factory transmit bundle number for DS3002s and DS3008s is 2.
4)
receive bundle ID:
The default factory receive bundle number for DS8000s is 2.
!
Mismatched transmit and receive bundle numbers will result in no audio being delivered. There can be only one system
Broadcaster for a given bundle. For example you could not have two DS3008s broadcasting on the same bundle number.
7)
soundmasking schedules:
Soundmasking schedules may be user defined to raise and lower soundmasking levels
based on time of day and day of the week. This setting applies a specific schedule to the DS8000. See Soundmasking
schedules for more information on modifying and enabling soundmasking schecules.
This feature requires a full time con-
nected PC.
8)
soft start schedule:
The
Soft Start schedule is a one-time schedule used to gradually introduce sound masking into
an existing non-masked office. This proecess is generally not required for new facilities. It is used to facilitate the addition
of soundmasking to an already lived-in environment.
This feature requires a full time connected PC controller.