Maintenance, 10h
4812160801_D.pdf
2018-12-17
Warning lamps - Check
Fig. Control panel.
Check that the warning lamps on the control panel
function.
Air cleaner indicator
Fig. Air cleaner
1. Indicator
1
If the indicator (1) on the air cleaner turns red, empty
the dust pouch (2) on the air cleaner. The dust pouch
is emptied by pressing the rubber bellows with your
fingers. Check also that the air hoses are in good
condition.
Clean the air cleaner when operated in extremely
dusty environments.
2
Fig. Air cleaner, right side
2. Dust pouch