Installation, Operation and Service Manual
LKP Series
TABLE 5.1
MEASURING HEAD RESISTANCE CHART -LKP-8024
Measure Between Leads:
Desired Value
Circuit
(Ohms)
CABLE TO “1” HALF OF HEAD
25 & 26
25-30
Hall Current - Channels 1, 2. 3
1 & 4
3-6
Hall Signal - Channel #1
5 & 6
3-6
Hall Signal - Channel #2
7 & 10
3-6
Hall Signal - Channel #3
27 & 34
10-12
Coil Circuit - Channel #1
28 & 35
10-12
Coil Circuit - Channel #2
29 & 36
10-12
Coil Circuit - Channel #3
39 & 40
Open
Over temperature Thermostat
CABLE TO “2” HALF OF HEAD
25 & 26
25-30
Hall Current - Channels 4, 5, 6
11 & 12
3-6
Hall Signal - Channel #4
13 & 16
3-6
Hall Signal - Channel #5B
17 & 18
3-6
Hall Signal - Channel #6
30 & 34
10-12
Coil Circuit - Channel #4
31 & 35
10-12
Coil Circuit - Channel #5
32 & 36
10-12
Coil Circuit - Channel #6
39 & 40
Open
Hall Current - Channels 5B through 1A
NOTES:
1. BUS CURRENT MUST BE ZERO when taking resistance measurements!
2. Use R x 1 ohmmeter scale. Measurements are made between cable leads listed, at Signal Converter
end of Cable and with leads disconnected from TS1.
3. The resistance readings will be slightly higher if the cable is over 30 feet in length. These resistance
readings are the room temperature values of the copper channel coils.
© 2011 DynAmp, LLC
Page 13
041837 H