Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003
63
4 Configuration
use
Serial
Console and Telnet with Menu
Driven Interface
4.1 Introduction
4.1.1
Login to the Console Interface
The console port is a RJ-48C connector that enables a connection to a PC for monitoring and
configuring the EFM modem. Use the supplied serial cable with a female DB-9 connector to
serial port of PC and RJ-48C module jack connector to EFM modem’s console port. Start your
terminal access program by terminal emulation program or Hyper Terminal and configure its
communication parameters to match the following default characteristics of the console port:
Parameter
Value
Baud rate
9600
Data Bits
8
Parity Check
None
Stop Bits
1
Flow-control
None
After finished the parameter settings, press the SPACE key until the login screen appears.
When you see the login screen, you can logon to this EFM Modem.
Note: Only SPACE key invoke the login prompt. Pressing other keys does not work.
The system asks for User and Password, please enter “admin” both for the factory default
password. As show in the following:
User: admin
Password: *****
4.1.2 Telnet
login
The EFM modem also supports telnet for remote management.
Make sure the correct Ethernet cable connected the MGMT port of EFM modem to your
computer. The MGMT indicator on the front panel shall light if a correct cable is used. Starting
your Telnet client with VT100 terminal emulation and connecting to the management IP of EFM
modem, wait for the login prompt appears. Input User and Password after login screen pop up.
The system asks for User and Password, please enter “admin” both for the factory default
password. As show in the following: