background image

4

Copyright © 2014 - 2017 Dynamic Projection Institute GmbH. All rights reserved. http://www.dynamicprojection.com

Weights and dimensions shown are approximate. Specifications and appearance are subject to change without notice. 

Version 1.8

Warnings and Safety

* This product shall only be connected to an external power supply 
rated at 5V dc, and a minimum current of 2A . Any external power 
supply used with the JCD shall comply with relevant regulations 
and standards applicable in the country of intended use.

* This product should not be overclocked as this may make 
certain components very hot.

* This product should be operated in a well ventilated environment 
and should not be covered.

* This product should be placed on a stable, flat, non-conductive 
surface in use and should not be contacted by conductive items.

* The connection of unapproved devices to the GPIO, USB, 
HDMI, Network or Audio connector may affect compliance or 
result in damage to the unit and invalidate the warranty.

Instructions for safe use

To avoid malfunction or damage to your JCD please observe the 
following:

* Do not expose it to water, moisture or place on a conductive 
surface whilst in operation.

* Do not expose it to heat from any source; the JCD is designed 
for reliable operation at normal ambient room temperatures.

* Take care whilst handling to avoid mechanical or electrical 
damage to the printed circuit board and connectors.

* Avoid handling the JCD while it is powered. Only handle by the 
edges to minimise the risk of electrostatic discharge damage.

* All peripherals used with the JCD should comply with relevant 
standards for the country of use and be marked accordingly to 
ensure that safety and performance requirements are met.

* The JCD is not designed to be powered from a USB port on other 
connected equipment, if this is attempted it may malfunction.

Compliance information

The JCD (Raspberry Pi) complies with the relevant provisions of 
the RoHS Directive for the European Union.

WEEE directive statement for the european union

In common with all Electronic and Electrical products the JCD 
(Raspberry Pi) should not be disposed of in household waste. 

Alternative arrangements may apply in other jurisdictions.

Emc compliance statements european union 
(eu) electromagnetic compatibility directive 
compliance statement

* This product is in conformity with the protection requirements 
of EU Council Directive 2004 / 108 / EC on the approximation 
of the laws of the Member States relating to electromagnetic 
compatibility.

* This product has been tested and found to comply with the 
limits for Class A Information Technology Equipment according 
to the European Standard EN 55022.

WARNING: This is an EN 55022 Class A product. In a domestic 
environment this product may cause radio interference in which 
case the user may be required to take adequate measures.

Federal communications commission (FCC) 
emissions compliance statement

* This equipment has been tested and complies with the limits 
for a Class A digital device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in 
a commercial environment.

* This device complies with Part 15 of the FCC Rules. Operation 
is subject to the following two conditions: (1) this device might 
not cause harmful interference, and (2) this device must accept 
any interference received, including interference that might 
cause undesired operation.

WARNING: Operation of this equipment in a residential area is 
likely to cause harmful interference, in which case the user will 
be required to correct the interference at their own expense

.

Industry canada class a emissions compliance 
statement

* This Class A digital apparatus complies with Canadian ICES-003.

Australia and new zealand class a emissions 
compliance statement

WARNING: This is a Class A product. In a domestic environment 
this product may cause radio interference in which case the 
user may be required to take adequate measures.

Содержание JCD

Страница 1: ...oximate Specifications and appearance are subject to change without notice Version 1 8 Version 1 8 JCD Manual VERSION 1 8 JCD 1 Copyright 2014 2017 Dynamic Projection Institute GmbH All rights reserve...

Страница 2: ...otice Version 1 8 Table of Content Introduction 3 Warranty 3 Warnings and Safety 4 JCD Control Unit 5 Physical Setup 6 Network Access 7 Web Interface 8 JCD Status 9 JCD Configuration Projector 10 JCD...

Страница 3: ...al product keep this manual for the entire service life of the product pass this manual on to every further owner or user of the product download the latest version of the user manual from our website...

Страница 4: ...with the relevant provisions of the RoHS Directive for the European Union WEEEdirectivestatementfortheeuropeanunion In common with all Electronic and Electrical products the JCD Raspberry Pi should n...

Страница 5: ...1 8 1 2 3 4 JCD Control Unit 1 2GHz Quad Core 64bit control unit with max power 12W 1 JCD Control Unit with internal WiFi accesspoint 802 11 b g n 2 Micro USB power socket 3 Network connector 4 USB 2...

Страница 6: ...Flip the power switch to turn the control unit on this will take a few seconds 4 optional For Ethernet connectivity plug in a CAT5 6 cable into the RJ45 jack 3 of the control unit and connect it to yo...

Страница 7: ...s as a Wi Fi hotspot you should be able to find a network named JCD xxxxxxxx with xxxxxxxx being a combination of numbers and letters The exact SSID as well as the WPA key can be found on a sticker on...

Страница 8: ...access enter the default IP address 192 168 1 1 for Wi Fi 2 0 0 20 for Ethernet in a browser of your choice The JCD splash screen should appear click on the logo to enter the web interface The web int...

Страница 9: ...very second On successful setup the system should be in the IDLE state meaning that JCD is ready and waiting to accept commands If the status is ERROR instead the USB to RS232 converter is not connect...

Страница 10: ...start the detection The autodetection will take some time information about the progress will be displayed below the button When the process is complete the message Probing finished will appear and t...

Страница 11: ...e 0 32767 Incoming DMX data from any other universe will be ignored The port which all JCD components use internally for communication default 7781 can be configured via the Control channel port optio...

Страница 12: ...number of steps are saved and displayed above the buttons The actual number of steps used will be slightly lower than the measured number the reduction either absolute number of steps or a percentage...

Страница 13: ...can now be controlled using the Focus Zoom Control tab To adjust the lens zoom or focus move and release the Zoom and Focus sliders While the lens Is moving the status will change to BUSY As soon as...

Страница 14: ...he Save Memory button and clicking on the button afterwards A confirmation is required to prevent accidental overwriting of already saved positions To move the lens to a previously saved position use...

Страница 15: ...ommand button To execute a command simply click on the corresponding button if an argument is available select the desired value by using the spinner buttons or directly entering it first NOTE Not all...

Страница 16: ...pt 16 bit arguments which are set by using the channel groups 3 4 5 6 7 8 9 10 11 and 12 13 14 The first channel represents the high byte of the 16 bit value the second channel represents the low byte...

Страница 17: ...out all incoming ArtNet DMX data on the selected network interface see the network configuration section for further information Only the last 50 log entries are available For the current universe the...

Страница 18: ...for download at http www dynamicprojection com jcd support To install an update simply download the update package named jcd update xxx zip and extract its contents onto an empty USB pen drive Remove...

Страница 19: ...TE CHANNEL 0 127 Not used 128 DO NOT USE 192 154 Not used 255 Execute on raise 2 COMMAND CHANNEL 0 254 See Command List in the manual 255 Reserved 3 ARGUMENT 1 HIGH 0 255 High Byte Value 4 ARGUMENT 1...

Страница 20: ...Function 1 EXECUTE CHANNEL 128 Instant Mode Commands will execute instantly 2 COMMAND CHANNEL 0 255 See Command List 255 DO NOT USE 3 ARGUMENT 1 HIGH 0 255 High Byte Value 4 ARGUMENT 1 LOW 0 255 Low B...

Страница 21: ...ce are subject to change without notice Version 1 8 DMX Fixture Head Personality Easy Mode Channel Value Function 1 EXECUTE CHANNEL 128 Instant Mode Commands will execute instantly 2 COMMAND CHANNEL 2...

Страница 22: ...a Email office dynamicprojection com Web www dynamicprojection com Phone 43 1 996 2028 Mo Fr from 9 00 to 18 00h Commercial Register FN400806x YouTube Training channel http www dynamicprojection com t...

Отзывы: