8)
Enter Creep Angle, parameter 42.
9)
Enter Stop Angle, parameter 43.
10) Enter Creep Speed, parameter 44.
11) Enter Max Speed, parameter 26.
12) Enter Initial Accel Rate, parameter 49.
13) Enter the Wrong Direction Limit, parameter 70.
c. Run the press through several cycles.
d. Use the stop-on-top function to stop the press.
Readjust the creep speed, creep angle, and stop
angle, if necessary, to attain the proper stopping
on top.
13. Run the Press in the Micro Inch Mode.
a. Enter the Micro Inch Speed, parameter 45.
b. Jog the press through one or more strokes.
c. Use the Inch pushbutton for this jog function.
14. Check the Remaining Faults.
APPROXIMATE PARAMETER SETTINGS
Approximate parameter settings, which are furnished for
trial only, are indicated in Table 4-1. Actual settings will
be determined during the press set-up. If, for security
reasons, the customer removes the ribbon cable
connecting the keypad to the DMR, care must be
exercised in removing the power to the DMR when
removing or replacing the cable. Otherwise, damage
may result to the unit.
A resume of serial interface commands from the press
control to the DMR is as follows:
AA Accept downloaded parameters that follow.
BB Send fault codes
CC Send monitor data.
DD Begin using parameters down loaded with last AA
commands
EE Echo back last AA parameters.
Содержание CES
Страница 7: ...7 ...
Страница 37: ...Page is intentionally blank ...