81 of 105
9.4
Engine Sending Units
Senders are required if display of engine parameters, warnings and failures are required.
Otherwise switches could be used if only failure indication and shutdown is required.
Table 22 – Senders Part List
Sender Description
Stock Code
Part # Description
Datcon – Oil Pressure (34 to 241
Ohms)
ACC0074
Datcon 102225-00 1/8” = 27
NPTF (Heavy duty version of
Datcon 2505-00)
Datcon – Temperature ( 7 to 491
Ohms), 1/8”
ACC0027
Datcon 02022-00 1/8”-27
NPTF
Datcon – Temperature, 3/8”
ACC0098
DATCON - 02024-00 3/8" 18
NPTF
Datcon – Temperature, 1/2”
ACC0099
DATCON - 02025-00 1/2" 14
NPTF
9.5
GSC400 replaceable 12/24VDC relays
The GSC400 controller is designed to operate in either 12 or 24 VDC battery start systems. When
operating in 12VDC systems the fuel, crank and extra relays need to be rated 12VDC coil. When
operating in 24VDC systems these relays need to be rated 24VDC coil. To maintain the UL
rating, the HASCO relays must be used.
Table 23 – Relay Part List
Relay Description
Stock Code
Manufacturer’s Part
No.
12VDC AZETTLER
RLY0029
AZ-973-1C-12DC
24VDC AZETTLER
RLY0043
AZ-973-1C-24DC
12VDC HASCO
RLY0053
CAR-1A-40-DC12S
24VDC HASCO
RLY0054
CAR-1A-40-DC24S
Содержание GSC400 Series
Страница 15: ...Figure 4 General GSC400 System Wiring Diagram ...
Страница 16: ...Figure 5 Digital IO Example ...
Страница 104: ...104 of 105 12 Appendix D Additional Drawings The follow pages include various drawings that may be of benefit ...
Страница 105: ...105 of 105 ...