Notice!
Only one PMX-MM-2 can be used in the DPM 8016.

Any of these slots can be used to install the extension cards; once they are installed, they are
automatically recognized by the DPM 8016.

Figure 7.1: Installation of an audio extension card

Network module slot
The network module slot on the rear panel of the DPM 8016 can be used to retrofit an audio
network interface to a CobraNet network. The CM-1 module used here has two Ethernet
connections to set up a redundant network.

Network configuration

The DPM 8016 can be connected to a TCP/IP network via the Ethernet interface on the rear
panel. For information regarding the basics of Ethernet and TCP/IP, see the Appendix, page
35
 to this document. The DPM 8016 has the following network configuration by default:

Parameter

Value

IP address

192.168.1.100

Subnet mask

255.255.255.0

Gateway

192.168.1.1

DHCP

Disabled

Table 7.1: Factory setting for Ethernet interface

An IP address must be unique, i.e., it must only be assigned to one device (host) in a network.
If a new Ethernet is established for operating the DPM 8016, we recommend retaining the
default network ID and subnet mask. When integrating the DPM 8016 into an existing
Ethernet, the network configuration of the DPM 8016 must be adjusted. The default IP
address of the DPM 8016 can be retained if

only one single DPM 8016 is connected with the default network configuration via
Ethernet, and

 

7.2

26

en | Configuration

DPM 8016

 

16-Dec-13 | 02 | F01U259190

Operation manual

 

Содержание DPM 8016

Страница 1: ...DPM 8016 en Operation manual...

Страница 2: ......

Страница 3: ...8 6 2 Ethernet 18 6 3 REMOTE CAN BUS 19 6 4 Control port 22 7 Configuration 25 7 1 Installing extension cards 25 7 2 Network configuration 26 8 Operation 28 9 Maintenance 29 10 Technical data 30 10 1...

Страница 4: ...the safety ground connection function of the supplied power cable If the plug of the supplied cable does not fit your mains socket please contact your electrician 10 Ensure that it is not possible to...

Страница 5: ...tomer service technician 1 Repair work on the device must comply with the safety standards specified in EN 60065 VDE 0860 2 A mains isolating transformer must be used during any work for which the ope...

Страница 6: ...Caution Risk of explosion if battery is not replaced correctly Must be replaced only with the same or equivalent type of battery 6 en Safety notes DPM 8016 16 Dec 13 02 F01U259190 Operation manual...

Страница 7: ...ules The DPM 8016 contains all necessary audio functions and is responsible for controlling and monitoring the complete PROMATRIX 8000 system A single DPM 8016 can manage up to 16 call stations and up...

Страница 8: ...the modular network capable central unit of the PROMATRIX 8000 system The system can be adjusted to system requirements via the 8 slots for audio input audio output or message manager modules The DPM...

Страница 9: ...r optimal sound adjustment of the audio sources All outputs are fitted with a 5 band equalizer and a limiter For the equalizers the operator can select from six different filter types for each band fi...

Страница 10: ...red Functions and parameters can be connected in an internal sequence The TaskEngine in the DPM 8016 provides a graphic display that allows the user to combine processes individually One example would...

Страница 11: ...ll stations The required number of call stations from the DPC 8000 series max 16 and the corresponding connecting cables 3 If the audio element of the device is to be used Power amplifier preferably f...

Страница 12: ...24 V DC input Phoenix PC 5 2 STF1 7 62 1777833 2 12 pole connector for GPIO Phoenix MC 1 5 12 STF 3 81 1827800 1 Warranty card with safety notes Table 4 1 Scope of delivery Warranty For information r...

Страница 13: ...tes yellow when the device is in standby mode 4 MASTER LED Illuminates green if this DPM 8016 controller is in the digital audio network of the master 5 FAULT LED This LED illuminates yellow during a...

Страница 14: ...ltage page 18 2 CONTROL PORT See Section Control port page 22 3 STATUS LED See Section REMOTE CAN BUS page 19 4 REMOTE CAN BUS interfaces 5 RS 232 interfaces See Section Connections page 17 6 ETHERNET...

Страница 15: ...xceeded When installing in a cabinet or transport rack standard installation rails should be used to prevent the front panel distorting The DPM 8016 must be protected from Dripping water or spray Dire...

Страница 16: ...Attachment on the front panel When installing in cabinet racks installation rails should always be used to prevent the front panel distorting 16 en Installation DPM 8016 16 Dec 13 02 F01U259190 Operat...

Страница 17: ...ion signals from entering the audio signal path especially buzzing Interface to call stations PCA BUS The PROMATRIX CAN Audio PCA BUS interface of a UI 1 universal input module connects a DPC 8015 cal...

Страница 18: ...our Support department Ethernet Connecting the DPM 8016 system controller via the Ethernet interface allows the DPM 8016 to communicate with one or more PCs This not only allows simple configuration o...

Страница 19: ...ler or an Ethernet switch The green network traffic LED on the right side of the Ethernet interface briefly illuminates each time Ethernet data is transferred Crossover cable When using a crossover ca...

Страница 20: ...ipes 7 MONITOR BUS Brown stripes 8 MONITOR BUS Brown Table 6 3 Assignment of the REMOTE CAN BUS interface Cable specification In accordance with the ISO 11898 2 standard shielded or unshielded twisted...

Страница 21: ...WG17 Table 6 5 REMOTE CAN BUS cable cross section If a participant cannot be directly connected to the CAN bus a stub line branch line must be used Since there must always be precisely two terminating...

Страница 22: ...freely programmable control inputs for voltages of between 0 volts and 10 volts The inputs are numbered 1 through 8 The DPM 8016 controller provides its own voltage supply for externally connected co...

Страница 23: ...200mA see also the following diagram Notice The voltage value used as the supply voltage for the DPM 8016 controller is always present on the 24 48V output Caution The maximum permissible power on th...

Страница 24: ...ximum load of the ready contact is 30 V 1 amp Radio clock input DCF77 The top half of the control port has an input for the radio receiver of the DCF77 signal We recommend using the DYNACORD NRS 90193...

Страница 25: ...r a DCS system connect the REMOTE CAN BUS interface of the DPM 8016 with the CAN devices See the Section REMOTE CAN BUS page 19 5 Connect the voltage supply of the DPM 8016 6 Activate the voltage supp...

Страница 26: ...f Ethernet and TCP IP see the Appendix page 35 to this document The DPM 8016 has the following network configuration by default Parameter Value IP address 192 168 1 100 Subnet mask 255 255 255 0 Gatew...

Страница 27: ...ist for the system described in the above diagram is given below The Appendix contains a blank form For each device used in the network enter the name of the device a unique description and the IP add...

Страница 28: ...Operation To operate the DPM 8016 see the IRIS Net documentation 8 28 en Operation DPM 8016 16 Dec 13 02 F01U259190 Operation manual...

Страница 29: ...Maintenance The DPM 8016 does not require any maintenance 9 DPM 8016 Maintenance en 29 Operation manual 16 Dec 13 02 F01U259190...

Страница 30: ...mplete audio systems Programmable user control panels and access levels Audio input specifications See technical specifications of used input module Audio output specifications See technical specifica...

Страница 31: ...M UI 1 Universal Input Module 100 g DPM AO 1 Analog Output Module 100 g PMX MM 2 Message Manager Module 85 g CM 1 CobraNet Module 75 g DPM Universal Input Module DPM UI 1 part number PDC 121856 2 anal...

Страница 32: ...dB 0 300 A 0 080 A 0 050 A 0 060 A 0 170 A Table 10 1 DPM 8016 power consumption at 24 V DC Power consumption of call stations For each DPC 8015 call station 0 080 A with active loudspeaker 0 190 A Fo...

Страница 33: ...UB Internal Expansion Slot CAN Host Bus Audio Out 16 Channels Audio In 16 Channels 9 pin D SUB AUDIO NETWORK PORT 2 x 12 pin Phoenix Remote CAN Interface 2 x RJ 45 AUDIO MODULES 2 8 Channels Analog I...

Страница 34: ...andards The DPM 8016 meets the following standards correct as of July 2012 EN 54 16 EN 55103 1 EN 55103 2 EN 55022 EN 55024 EN 60945 10 3 10 4 34 en Technical data DPM 8016 16 Dec 13 02 F01U259190 Ope...

Страница 35: ...195 Leading zeros can also be omitted so that the above example can also be written as 130 9 122 195 The following table shows address ranges that should be used in private networks Private IP address...

Страница 36: ...zeros or entirely of ones in binary form Example In the example IP address of 130 9 122 195 with a subnet mask of 255 255 255 0 given above the network element would be 130 9 122 0 Each device or inte...

Страница 37: ...IP addresses Project ________________________________________ Subnet mask Gateway Device Name in IRIS Net Location Description IP address 11 2 DPM 8016 Appendix en 37 Operation manual 16 Dec 13 02 F0...

Страница 38: ......

Страница 39: ......

Страница 40: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www dynacord com Bosch Sicherheitssysteme GmbH 2013...

Отзывы: