Configuration
IRIS-Net
IRIS-Net PC software (Intelligent Remote & Integrated Supervision) is used to configure and
operate the DPM 8016. It enables the overall configuration of the DPM 8016 to be performed
off-line using a PC (i.e., without establishing a connection between the PC and DPM 8016).
The configuration can then be transferred by establishing a connection between the PC and
DPM 8016 via Ethernet. In addition to configurations, IRIS-Net can also be used for
comprehensive checking and monitoring of a PROMATRIX 8000 system. For more information
about installing IRIS-Net on your PC, see the file “iris_readme.pdf”. During the installation, the
IRIS-Net user manual is automatically copied to the PC.
Set-up process
1.
Install the extension cards. If you have acquired extension cards (e.g., UI-1, AO-1, CM-1,
PMX-MM-2) for your DPM 8016, install these. See the Section Installing extension cards,
page 25.
2.
If extension cards with inputs or outputs (UI-1, AO-1 or CM-1) were installed in step 1,
connect the devices to be used. Follow the documentation for the extension cards and
the devices used.
3.
Connect the Ethernet interface of the DPM 8016 controller with the PC via a suitable
Ethernet cable. See the Section Ethernet, page 18.
4.
If your application includes CAN devices such as DPA amplifiers or a DCS system, connect
the REMOTE CAN BUS interface of the DPM 8016 with the CAN devices. See the Section
REMOTE CAN BUS, page 19.
5.
Connect the voltage supply of the DPM 8016.
6.
Activate the voltage supply of the DPM 8016, and activate the additional connected
devices if applicable.
7.
Install the IRIS-Net (Intelligent Remote & Integrated Supervision) program on the PC. See
the installation instructions for IRIS-Net in the file iris_readme.pdf.
8.
Start IRIS-Net on your PC.
Installing extension cards
This chapter describes the options for expanding the DPM 8016 with extension cards. The
DPM 8016 can be assigned extension cards in various ways:
•
8 slots (extension slots) for enhancing the system with analog audio inputs (UI-1), analog
audio outputs (AO-1) or one message manager (PMX-MM-2)
•
1 network module slot for installing an audio network module (e.g., CM-1 CobraNet
module)
!
Caution!
The DPM 8016 must always be isolated from the supply voltage if you intend to install a
module. For precise installation instructions, see the description of the respective module.
Extension slots
Eight slots, which are numbered 1 through 8, are available on the rear panel of the DPM 8016
for extending the system. These slots allow any combination of extension cards of the
following types:
•
DPM UI-1 universal input module with 2 analog audio inputs
•
DPM AO-1 analog output module with 2 analog audio outputs
•
PMX-MM-2 message manager module
7
7.1
DPM 8016
Configuration | en
25
Operation manual
16-Dec-13 | 02 | F01U259190