2 8
U S E R G U I D E
|
B L U E W A V E
®
Q X 4
®
Outputs
Note: Output pins require a 10K pull up resistor to customer supplied 24V depending
on load, contact Application Engineering for issues related to choosing resistors.
Signal Name/
Description
Asserted
Deasserted
0V
24V
LED STATUS 1 ->4
EXPOSURE 1->4 is
asserted.
EXPOSURE 1->4 is de-
asserted.
LED STATUS ALL
EXPOSURE ALL is
asserted.
EXPOSURE ALL is de-
asserted.
WARNING
Any LED head is in alarm or
the controller is in alarm.
Warning screen will be
displayed. Front panel will
be locked. All LED heads
will be turned off. All LED
heads will be disabled.
No LED heads or the
controller are in alarm.
INTERLOCK STATUS
INTERLOCK Input is
asserted.
INTERLOCK Input is de-
asserted.
INHIBIT STATUS 1->4
INHIBIT 1->4 is asserted.
INHIBIT 1->4 is de-asserted.
COM
Reference Ground Pin
OUTPUT RESERVE 1
Not used at this time
Figure 22.
PLC Wire Attachment, Terminals Installed