U S E R G U I D E
|
B L U E W A V E
®
Q X 4 V 2 . 0
27
Inputs
Signal Name/
Description
Asserted
Deasserted
0V
24V
PLC ENABLE
The unit enters PLC mode.
The front panel will display
the PLC screen. The front
panel will be locked. All PLC
inputs will be monitored. All
PLC Outputs will be active.
The unit enters normal mode.
The front panel will be
unlocked. All PLC Inputs will
be ignored. All PLC Outputs
will be inactive.
EXPOSURE 1->4
LED head “n” will turn on.
LED head “n” will turn off.
EXPOSURE ALL
All LED heads will turn on.
All LED heads will turn off.
INHIBIT 1->4
LED head
“n” will function
normally.
LED head “n” will turn off.
MASTER
INTERLOCK
All LED heads will function
normally.
Front panel displays lock
screen. Front panel will be
locked. All heads will be shut
off.
PROG/ANALOG
Control the output power
through the external analog
signal.
Use the set power parameters
on UI.
ANALOG
INTENSITY
0-10V, DC input.
INPUT RESERVE 1
Not used at this time
COM
User signal ground