U S E R G U I D E
|
B L U E W A V E
®
Q X 4 V 2 . 0
19
Operation
WARNING!
Looking directly at the high-intensity light emitted by the
heads of the BlueWave QX4 V2.0 can result in eye injury. To prevent eye
injury, never look directly at the high-intensity light and always wear
protective goggles (provided).
Verify that all connectors are firmly plugged
into the rear panel of the unit. See
System
Connections
, pg. 16 for more details.
On the rear panel of the controller, move
the Power Switch to the on position (I). The
system is now ready for use.
On the first startup, the system defaults to
ADMIN mode. The boot mode can be set
through the User Interface in System
Settings .
ADMIN Mode
ADMIN mode allows the user to configure
each LED head at a predefined (constant)
power output for a given amount of time.
Each head can be adjusted independently.
If the current mode is not ADMIN
mode, you need to enter the password
to return to the ADMIN mode.
Default Password:1234
Figure 9.
Main Menu Screen in ADMIN
Mode
Figure 10.
Return to ADMIN Mode by
Entering the Password