U S E R G U I D E
|
B L U E W A V E
®
Q X 4 V 2 . 0
29
Wiring PLC
When wiring the PLC connectors, use wires no larger than 20 AWG. Strip the wire
back approximately 8-mm to insert into the connector clamp.
Ensure the connector wire clamp is open by unscrewing the clamp screw, if needed,
and insert the wire. Tighten the clamp screw to lock the wire in place.
Example Setup
The following is an example of how to set up the BlueWave QX4 V2.0 LED head
controls to operate individually. (e.g. channel 1)
1.
Set your individual LED head channels to the desired power level and exposure
time using the touchscreen.
2.
Connect an output of the PLC to PLC Enable (Pin1) and GND to Com (Pin2) of the
BlueWave QX4 V2.0
PLC interface. This will put the controller into PLC control
mode.
3.
For one channel (e.g., channel1), connect other PLC outputs to the Pin3, Pin13, and
Pin21.
Figure 23.
Connection Diagram