Wiring and Connections
All the wire and cable connections are located on the rear of the controller or the top of emitter.
Figure 8.
Controller Connections
Power Switch:
Turns the unit on and off.
Power Input:
The power cord plugs in here. Only use the power cord supplied by Dymax (Figure 9) as the power cord
supplied with the controller is specifically designed and certified to work with the controller.
WARNING!
The BlueWave FX-1250 is designed and certified to operate with the Dymax supplied 16 Amp, 1.5 mm², 3
conductor power cord. Do not use any other non-standard power cord.
Figure 9.
Power Cord
Figure 10.
Connection Cable for Output Channels 1 & 2
Output CH1/CH2:
Output power and control signal to emitter. Only use the connection cable supplied by Dymax (Figure 10)
as the connection cable supplied with the controller is specifically designed for this system. One controller in 2CH
configuration can support up to two emitters at the same time.
SWD:
Burn in or update the software into controller.
RS232:
Conduct communication to computer.
PLC:
Controlled by PLC program.
RS485
: Controlled by internet.
Output CH1
Power Input
Output CH2
Power Switch
RS485
RS232
SWD
PLC