System Installation
System Assembly
The system includes two major parts, the controller and
emitter. The two parts are shipped separately.
To assemble the two parts together, plug one side of the
connection cable into the controller and the other side
into the emitter (Figure 6).
NOTE:
Be careful to keep the glass at the bottom of the
emitter clean. To avoid leaving fingerprints on the glass,
do not touch the glass with bare hands.
WARNING!
The BlueWave FX-1250 is
designed and certified to operate as instructed
within this document. Alteration of the system or
its component installation may pose a shock
hazard.
Figure 6.
Connection Cable Installed
System Cooling
The system can be used in various scenarios with additional mounting fixtures or Dymax accessories, i.e., as a bench-top unit
with a stand on a chamber, as part of a conveyor, etc. This system should only be operated in a location that provides proper
cooling. Location requirements are as follows:
•
For proper cooling of the unit, upper intake and lower exhaust must not be blocked.
•
Minimum recommended clearance is 8 inches [200 mm].
•
Note that the lower exhaust may have one side blocked for installations where two units are side by side. The system will
operate safely but run hotter.
Figure 7.