MesCom
– Workshop Manual – D6000/i14/V10
© Dycon Ltd 2014
-
58
7.7.31
MAXSKIPS
The maximum number of consecutive events to skip. To reduce the number of SMS sent by
the MesCom if consecutive stored events are for the same point, the earlier message will be
skipped.
Minimum 0, maximum 255.
Factory default: 8 events
9876 OPTION MAXSKIPS 8
7.7.32
MAXUPLOAD
Maximum number of events to upload in one batch. If multiple events are to be uploaded,
the time taken to send them to a server could hold up sending and receiving of SMS by the
MesCom. If the responsiveness of the MesCom to SMS is important so data connections are
unreliable, set this to a low number - this will cause the MesCom to end the connection,
check SMS and reconnected to send more event logs.
Minimum 0, maximum 255.
Factory default: 50 events
9876 OPTION MAXUPLOAD 50
7.7.33
TIME
Allow the time to be manually set. Depending on clock settings this time could be over
written when the clock is synchronised.
Time and date in the 24-hour format: dd/mm/yy,HH:MM:SS±zzzz
Where
dd
– day of the month.
mm
– month of the year (number eg December = 12).
yy
– last 2 digits of year (eg.2021=21).
HH
– hour of the day in 24 hour format (eg 1pm = 13, midnight = 00).
MM
– minutes past the hour.
SS
– seconds past the minute.
±zzzz
– time zone in the 4 digit 24 hour format (eg 1 hour ahead of GMT is +0100).
Please note: time zone reference is always GMT (also referred to as UTC) and never
daylight saving time (eg BST).
9876 OPTION TIME 23-01-14,13:45:45+0100
Also see CKSRC and CKINT parameters for more control of MesCom clock.
7.7.34
PIN
Set the PIN for the SIM card
– does not change the PIN on the SIM card itself and is only
used if the SIM card requires a PIN. If the stored PIN fails to unlock the SIM, the stored PIN
will be deleted. (Typically this command will only be used from terminal interface.).
Factory default: 0000
9876 OPTION PIN 12345678